Background: Roux-en-Y hepaticojejunostomy (RYHJ) is usually required for major bile duct injury (BDI) as a definitive treatment. Hepaticojejunostomy anastomotic stricture (HJAS) is the most feared long-term complication following RYHJ. The ideal management of HJAS remains undefined. The provision of permanent endoscopic access to the bilio-enteric anastomotic site can make endoscopic management of HJAS feasible and attractive option. In this cohort study, we aimed to evaluate short- and long-term outcomes of subcutaneous access loop created adjunct to RYHJ (RYHJ-SA) for management of BDI and its usefulness for endoscopic management of anastomotic stricture if occurred.

Materials And Methods: This is a prospective study including patients who were diagnosed with iatrogenic BDI and underwent hepaticojejunostomy with subcutaneous access loop between September 2017 and September 2019.

Results: This study included a total number of 21 patients whom ages ranged between 18 and 68 years. During follow-up, three cases had HJAS. One patient had the access loop in subcutaneous position. Endoscopy was done but failed to dilate the stricture. The other 2 patients had the access loop in subfascial position. Endoscopy of them failed to enter the access loop due to failure of fluoroscopy to identify the access loop. The three cases underwent redo-hepaticojejunostomy. Parajejunal (parastomal) hernia occurs in 2 patients in whom the access loop was fixed subcutaneous position.

Conclusion: In conclusion, modified RYHJ with subcutaneous access loop (RYHJ-SA) is associated with reduced quality of life and patient satisfaction. Moreover, its role in endoscopic management of HJAS after biliary reconstruction for major BDI is limited.

Download full-text PDF

Source
http://dx.doi.org/10.1177/00031348231173945DOI Listing

Publication Analysis

Top Keywords

access loop
36
subcutaneous access
16
management hjas
12
endoscopic management
12
access
10
loop
9
loop created
8
created adjunct
8
bile duct
8
duct injury
8

Similar Publications

The novel coronavirus (COVID-19) has affected more than two million people of the world, and far social distancing and segregated lifestyle have to be adopted as a common solution in recent years. To solve the problem of sanitation control and epidemic prevention in public places, in this paper, an intelligent disinfection control system based on the STM32 single-chip microprocessor was designed to realize intelligent closed-loop disinfection in local public places such as public toilets. The proposed system comprises seven modules: image acquisition, spraying control, disinfectant liquid level control, access control, voice broadcast, system display, and data storage.

View Article and Find Full Text PDF

Introduction: Trauma and orthopedics departments have traditionally used face-to-face (FTF) fracture clinics for non-operative fractures. Developed in 2011, the virtual fracture clinic (VFC) was fully implemented at an institution during the COVID-19 pandemic to reduce in-person interactions.

Aims: First, the study aims to measure the percentage of non-operative patients triaged through the VFC when this was optional and re-audit after implementing a COVID-19-related policy change mandating VFC triage.

View Article and Find Full Text PDF

A case report on the loss of an Iglesias resectoscope beak during hysteroscopic myomectomy.

J Minim Access Surg

December 2024

Maternal and Child Department, Complex Operative Unit of Obstetrics and Gynecology, Hospital of Gubbio and Gualdo Tadino, ASL 1 Umbria, Perugia, PG, Italy.

This case report describes the dynamics of the detachment of the ceramic beak of an Iglesias resectoscope that was lost in the uterine cavity during 'cold loop' hysteroscopic myomectomy. Our aim is to increase awareness of this issue and caution our colleagues against using Iglesias resectoscopes for hysteroscopies. The ceramic beak of an Iglesias resectoscope can detach itself if hard tissue is encountered during operative hysteroscopy.

View Article and Find Full Text PDF

Sutureless Loop Enterostomy in Very Low and Extremely Low Birth Weight Infants.

Cureus

November 2024

Department of Hepato-Biliary-Pancreatic Surgery and Pediatric Surgery, Saitama Medical Center, Saitama Medical University, Kawagoe, JPN.

Introduction Sutureless enterostomy is used as an effective technique for constructing an enterostomy in very low and extremely low birth weight infants in Japan. Sutureless enterostomy is a separate type of enterostomy procedure for low birth weight infants. We adapted this technique and developed sutureless loop enterostomy (SLE), an approach without a skin bridge in which the intestinal wall is not sutured to the abdominal wall.

View Article and Find Full Text PDF

FcγRI plays a crucial role in the effector function of IgG antibodies, interacting with the lower hinge region of IgG1 with nanomolar affinity. Binding occurs specifically in domain 2 (D2) of the FcγRI ectodomain, while domain 3 (D3) is a flexible linker. The D3 domain is positioned away from the IgG binding site on the FcγRI and does not directly contact the Fc region.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!