While recording surface electromyography [sEMG], it is possible to record the electrical activities coming from the muscles and transients in the half-cell potential at the electrode-electrolyte interface due to micromovements of the electrode-skin interface. Separating the two sources of electrical activity usually fails due to the overlapping frequency characteristics of the signals. This paper aims to develop a method that detects movement artifacts and suggests a minimization technique. Towards that aim, we first estimated the frequency characteristics of movement artifacts under various static and dynamic experimental conditions. We found that the extent of the movement artifact depended on the nature of the movement and varied from person to person. Our study's highest movement artifact frequency for the stand position was 10 Hz, tiptoe 22, walk 32, run 23, jump from box 41, and jump up and down 40 Hz. Secondly, using a 40 Hz highpass filter, we cut out most of the frequencies belonging to the movement artifacts. Finally, we checked whether the latencies and amplitudes of reflex and direct muscle responses were still observed in the highpass-filtered sEMG. We showed that the 40 Hz highpass filter did not significantly alter reflex and direct muscle variables. Therefore, we recommend that researchers who use sEMG under similar conditions employ the recommended level of highpass filtering to reduce movement artifacts from their records. However, suppose different movement conditions are used. In that case, it is best to estimate the frequency characteristics of the movement artifact before applying any highpass filtering to minimize movement artifacts and their harmonics from sEMG.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jelekin.2023.102778 | DOI Listing |
Atten Percept Psychophys
January 2025
U.S. DEVCOM Army Research Laboratory, Humans in Complex Systems, Aberdeen Proving Ground, MD, USA.
Historically, electrophysiological correlates of scene processing have been studied with experiments using static stimuli presented for discrete timescales where participants maintain a fixed eye position. Gaps remain in generalizing these findings to real-world conditions where eye movements are made to select new visual information and where the environment remains stable but changes with our position and orientation in space, driving dynamic visual stimulation. Co-recording of eye movements and electroencephalography (EEG) is an approach to leverage fixations as time-locking events in the EEG recording under free-viewing conditions to create fixation-related potentials (FRPs), providing a neural snapshot in which to study visual processing under naturalistic conditions.
View Article and Find Full Text PDFInvest Radiol
January 2025
From the Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany (A. Schwarz, A. Simon, A.M.); Siemens Healthineers AG, Forchheim, Germany (A. Schwarz, C.H., J.D., A. Simon); Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany (F.K.W., S.G., M.S.); and Institut for Radiology, Pediatric and Neuroradiology, Helios Hospital, Schwerin, Germany (H.-J.R.).
Objective: Respiratory motion can affect image quality and thus affect the diagnostic accuracy of CT images by masking or mimicking relevant lung pathologies. CT examinations are often performed during deep inspiration and breath-hold to achieve optimal image quality. However, this can be challenging for certain patient groups, such as children, the elderly, or sedated patients.
View Article and Find Full Text PDFHum Brain Mapp
February 2025
Computational Imaging Research Lab, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria.
Irregular and unpredictable fetal movement is the most common cause of artifacts in in utero functional magnetic resonance imaging (fMRI), affecting analysis and limiting our understanding of early functional brain development. The accurate detection of corrupted functional connectivity (FC) resulting from motion artifacts or preprocessing, instead of neural activity, is a prerequisite for reliable and valid analysis of FC and early brain development. Approaches to address this problem in adult data are of limited utility in fetal fMRI.
View Article and Find Full Text PDFInt J Retina Vitreous
January 2025
Department of Ophthalmology and Visual Sciences, Federal University of São Paulo (UNIFESP), Rua Botucatu, 822, Vila Clementino, São Paulo/SP, 04023-062, Brazil.
Background: Ozurdex® (Allergan®, AbbVie Company, North Chicago, Illinois, EUA), is composed of 0.7 mg of dexamethasone, fused in a solid biodegradable PLGA polymer, whose degradation occurs naturally in the vitreous cavity, usually in six months after its application.
Methods: In this study, we included patients aged ≥ 18 years with one or two eyes who had an indication for Ozurdex implants.
Functional magnetic resonance imaging (fMRI) of the spinal cord is relevant for studying sensation, movement, and autonomic function. Preprocessing of spinal cord fMRI data involves segmentation of the spinal cord on gradient-echo echo planar imaging (EPI) images. Current automated segmentation methods do not work well on these data, due to the low spatial resolution, susceptibility artifacts causing distortions and signal drop-out, ghosting, and motion-related artifacts.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!