In this report, we describe the first national scale multi-laboratory evaluation of monkeypox virus (MPXV) DNA commercial PCR kits. The objective of this study was to evaluate 2 kits by different diagnostic laboratories across Israel. Ten standardized samples were tested simultaneously using the Novaplex (15 laboratories) and Bio-Speedy (seven laboratories) kits. An in-house assay based on previously published reactions was used as reference. Comparison of the results showed high intra-assay agreement between laboratories, with small variations for most samples. The in-house assay had an analytical detection limit of less than 10 copies per reaction. While the 2 commercial kits were able to detect specimens with low viral loads similarly to the in-house assay, significant differences were observed, in the Cq values and relative fluorescence (RF), between the assays. The RF signal of the in-house and Bio-Speedy assays ranged between 5,000 and 10,000 RFU, while the signal in the Novaplex assay was less than 600 RFU. Due to the kit measurement protocol, the Cq values of the Bio-Speedy kit were 5 to 7.5 cycles lower than those of the in-house assay. On the contrary, the Cq values of the Novaplex kit were significantly higher than those of the in-house assay, with differences of 3 to 5 cycles per sample. Our results suggest that while all assays were similar in their overall sensitivity, direct comparison of Cq values between them may be misleading. To our knowledge, this is the first methodical evaluation of commercial MPX test kits. We therefore anticipate that this study would help diagnostic laboratories in choosing a specific MPX detection assay. To the best of our knowledge, this study is the first methodical evaluation of commercial kits designed for Monkeypox virus detection. This was done by performing the same tests using the same sample set in multiple laboratories, simultaneously, on a national scale. It therefore provides important and unique information on the performance of such kits and provides a guideline for choosing the assay of choice for monkeypox virus diagnosis in a standard diagnostic laboratory. It also demonstrates potential complications when trying to compare the results of different assays, even when testing exactly the same samples, under identical conditions.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10269769 | PMC |
http://dx.doi.org/10.1128/spectrum.00225-23 | DOI Listing |
Gait Posture
December 2024
The Robert Jones and Agnes Hunt Orthopaedic Hospital, NHS Foundation Trust, Oswestry, SY10 7AG, United Kingdom; School of Pharmacy and Bioengineering, Keele University, Guy Hilton Research Centre, Thornburrow Drive, Stoke-on-Trent, ST4 7QB. Electronic address:
Background: Electromyography (EMG) can estimate the magnitude and timing of muscle activation during walking in those with gait disorders. Despite the potential of EMG use in assessment and clinical decision-making, there are reports of declining use of EMG within gait laboratories. Technical and educational barriers to EMG usage in clinics in Italy were recently suggested.
View Article and Find Full Text PDFMikrochim Acta
December 2024
Department of Analytical Chemistry and Food Technology, Environmental Sciences Institute (ICAM), University of Castilla-La Mancha, Avda. Carlos III S/N, 45071, Toledo, Spain.
Single particle inductively coupled plasma mass spectrometry (SP-ICP-MS) is a powerful tool for metallic nanoparticle (NP) characterisation in terms of concentration and, taking into account several assumptions, also size. However, this technique faces challenges, such as the intrinsic matrix effect, which significantly impact the results when analysing real complex samples. This issue is critical for the calculations of key SP-ICP-MS parameters ultimately altering the final outcomes.
View Article and Find Full Text PDFJ Pharm Biomed Anal
December 2024
Hebei Provincial Hospital of Traditional Chinese Medicine, Shijiazhuang 050000, China. Electronic address:
Congelex Laxative Granules is an in-house preparation of Hebei Provincial Hospital of Traditional Chinese Medicine. This study aims to establish the HPLC fingerprint of Congelex Laxative Granules and evaluate its quality using chemometric methods. The Agilent Eclipse Plus C18 column and a methanol-water gradient elution system were employed, with detection at 224 nm.
View Article and Find Full Text PDFMicrobiome
December 2024
MOE Key Laboratory of Bio-Intelligent Manufacturing, School of Bioengineering, Dalian University of Technology, Dalian, Liaoning, 116024, China.
Acta Neuropathol Commun
December 2024
Michigan Center for Translational Pathology, University of Michigan, Ann Arbor, MI, USA.
We identified a rare heterozygous germline loss-of-function variant in the tumor necrosis factor receptor-associated factor 2 (TRAF2) in a young adult patient diagnosed with medulloblastoma. This variant is located within the TRAF-C domain of the E3 ubiquitin ligase protein and is predicted to diminish the binding affinity of TRAF2 to upstream receptors and associated adaptor proteins. Integrative genomics revealed a biallelic loss of TRAF2 via partial copy-neutral loss-of-heterozygosity of 9q in the medulloblastoma genome.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!