Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The introduction of the Luminex Crossmatch assay (LumXm) which uses Luminex bead technology, consists of extracting the donor's Human Leukocyte Antigen (HLA) molecules from their lymphocytes, and binding them to fluorescent beads that are put in contact with recipient's serum. HLA donor-specific antibodies (DSA) are detected using a fluorescent conjugate. The goal of our study is to determine the benefits of using LumXm in a renal transplantation algorithm. We tested 78 recipients' sera using the LumXm, and the results were compared with the Luminex single antigen bead assay (SAB) for all sera, as well as the Flow Cytometry Crossmatch (FCXM) for 46 sera. We compared our results with those of SAB using 3 cutoffs, the first being the manufacturer's criteria where sensitivity and specificity were at 62.5% and 91.3% respectively for HLA class 1, and 88.5% and 50.0% respectively for HLA class 2. When using the third cutoff criteria (≥2 Adjusted values + MFI [Mean fluorescence intensity] >500 + Neg MFI < 500), the sensitivity increased to 69.0% for HLA class 1 and decreased to 84.0% for HLA class 2, while the specificity increased for HLA class 1 and 2. When comparing with FCXM, the 3 assays agreed in 55.8% of results for class 1 and 2 alike. However, major discrepancies were found for two groups in HLA class 1 and one in HLA class 2. The LumXm when used with other techniques to overcome its' weak points, can provide an interesting insight into the patient's HLA-DSA profile.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/sji.13279 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!