  • * Intra-abdominal sepsis increases the difficulty of diagnosing NOMI and is a significant risk factor that can lead to intestinal necrosis.
  • * The review highlights recent advancements in diagnosing NOMI and stresses the importance of recognizing the diagnostic challenges in patients with abdominal sepsis.

Article Abstract

Non-occlusive mesenteric ischemia (NOMI) is a type of acute mesenteric ischemia (AMI) with a high mortality rate mainly because of a delayed or misdiagnosis. Intra-abdominal sepsis is one of the risk factors for developing NOMI, and its presence makes early diagnosis much more difficult. An increase in routine abdominal surgeries carries a corresponding risk of abdominal infection, which is a complication that should not be overlooked. It is critical that physicians are aware of the possibility for intestinal necrosis in abdominal sepsis patients due to the poor survival rate of NOMI. This review aims to summarize advances in the diagnosis of NOMI, and focuses on the diagnostic challenges of mesenteric ischemia in patients with intra-abdominal sepsis.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10148637PMC
http://dx.doi.org/10.7717/peerj.15307DOI Listing

Publication Analysis

Top Keywords

mesenteric ischemia
16
intra-abdominal sepsis
12
advances diagnosis
8
non-occlusive mesenteric
8
sepsis patients
8
diagnosis non-occlusive
4
mesenteric
4
ischemia
4
ischemia challenges
4
challenges intra-abdominal
4

Similar Publications

Gene therapy targeting ischemic heart disease is a promising therapeutic avenue, but it is mostly restricted to viral-based delivery approaches which are limited due to off-target immunological responses. Focused ultrasound presents a non-viral, image-guided technique in which circulating intravascular microbubble contrast agents can reversibly enhance vascular permeability and gene penetration. Here, we explore the influence of flow rate on the microbubble-assisted delivery of miR-126, a potent pro-angiogenic biologic, using a custom acoustically coupled pressurized mesenteric artery model.

View Article and Find Full Text PDF

Selective Minimally Invasive Strategy for Acute Superior Mesenteric Artery Obstruction.

J Vasc Surg

January 2025

Department of Vascular Surgery, Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University. Electronic address:

Objective: Acute mesenteric artery obstruction is a severe cause of acute mesenteric ischemia, associated with significant morbidity and mortality. However, there is limited guidance on choosing between traditional and minimally invasive techniques comprehensively. This study introduces a selective, minimally invasive strategy designed to improve the survival and prognosis of patients with acute superior mesenteric artery obstruction.

View Article and Find Full Text PDF

Plasminogen activator inhibitor-1 (PAI-1) is central to fibrinolysis regulation, and genetic variants such as the 4G/4G genotype predispose individuals to hypercoagulability. This case highlights a 46-year-old female patient presenting with acute mesenteric venous thrombosis, where genetic evaluation revealed homozygosity for the PAI-1 4G/4G polymorphism. Management with unfractionated heparin followed by a transition to direct oral anticoagulants led to clinical resolution.

View Article and Find Full Text PDF

We present a case of an 86-year-old female with chronic mesenteric ischemia secondary to long-segment flush occlusion of the superior mesenteric artery and near-total occlusion of the celiac artery. The superior mesenteric artery was unable to be revascularized by conventional antegrade approaches. Successful transcollateral crossing of the occluded superior mesenteric artery and body-flossing, followed by antegrade balloon angioplasty, shockwave lithotripsy, and stent implantation were performed.

View Article and Find Full Text PDF

We report a case of mesenteric ischemia after thoracic endovascular aortic repair (TEVAR) for chronic type B aortic dissection performed at a different institution. Computed tomography angiography findings indicated that the previous TEVAR had been deployed distally into the false lumen. To mitigate this, a large fenestration was created between the false lumen and true lumen.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!