Single-photon emission computed tomography with X-ray computed tomography (SPECT/CT) systems have diversified due to the remarkable developments made by each manufacturer. This study aimed to optimize the reconstruction parameters of six state-of-the-art SPECT/CT systems and compare their image quality of bone SPECT. SPECT images were acquired on SPECT/CT systems, including Symbia Intevo, Discovery NM/CT 670, Discovery NM/CT 870 CZT, Brightview XCT, and VERITON-CT. SIM bone phantom with tough lung phantoms on both sides of the spinal inserts that simulate the thorax was used for image quality assessment. SPECT images were obtained at individual workstations using an ordered subset expectation maximization method with three-dimensional resolution recovery, as well as CT attenuation and scatter correction, subset 2, iteration 12-84, and a full width at half maximum 10-mm Gaussian smooth filter. An automatic image analysis software dedicated to SIM bone phantom was used to assess the contrast-to-noise ratio (CNR), relative recovery coefficient, percentage of coefficient of variance, contrast, and detectability. The optimal parameters for each system were defined with superior detectability of spherical lesions and noise characteristics, as well as the highest CNR. All systems exhibited better image quality indexes using the optimal parameters than using the manufacturer's recommended parameters. The detectability of all systems was in agreement while using the optimal parameters. Detectability agreement can be achieved by optimizing the reconstruction parameters for different reconstruction algorithms, which can further improve the image quality. Therefore, future research should focus on optimal reconstruction parameters for SPECT alone.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s13246-023-01257-0 | DOI Listing |
Diagnostics (Basel)
December 2024
Department of Medicine I, University Hospital Munich, Ludwig-Maximilians-University, 81377 Munich, Germany.
: Iodo-metaiodobenzylguanidine single photon emission computed tomography/computed tomography (I-MIBG SPECT/CT) is used to evaluate the cardiac sympathetic nervous system in cardiac diseases such as arrhythmogenic right ventricular cardiomyopathy (ARVC) and α-synucleinopathies such as Parkinson's diseases. A common feature of these diseases is denervation. We aimed to compare quantitative and semi-quantitative cardiac sympathetic innervation using I-MIBG imaging of ARVC and α-synucleinopathies.
View Article and Find Full Text PDFEur Thyroid J
January 2025
G Treglia, Repubblica e Cantone Ticino Ente Ospedaliero Cantonale, Bellinzona, Switzerland.
Background: In relapsing differentiated thyroid cancer (DTC), the in vivo evaluation of natrium-iodine symporter (NIS) expression is pivotal in the therapeutic planning and is achieved by [131/123I]Iodine whole-body scan. However, these approaches have low sensitivity due to the low sensitivity due to the low resolution of SPECT. [18F]Tetrafluoroborate (TFB) has been proposed as a viable alternative, which could outperform [131/123I]Iodine scans owing to the superior PET resolution.
View Article and Find Full Text PDFAsian J Endosc Surg
January 2025
Department of Obstetrics and Gynecology, Kyushu University Hospital, Fukuoka, Fukuoka, Japan.
Introduction: This study examined factors that affected sentinel lymph node (SLN) identification of patients with endometrial cancer having a preoperative estimation of low recurrent risk.
Methods: This study included 97 patients with endometrial cancer who attempted to identify SLN using a uterine cervical injection of technetium-99 m phytate under laparoscopic or robotic-assisted surgery at our institute. A preoperative single photon emission computed tomography (SPECT) and intraoperative gamma probe were used to detect hot nodes.
Curr Top Behav Neurosci
January 2025
Pharma Research and Early Development (pRED), Roche Innovation Center Basel, F. Hoffmann-La Roche Ltd, Basel, Switzerland.
Cannabis sativa has been used therapeutically since early civilizations, with key cannabinoids Δ-tetrahydrocannabinol (THC) 3.1 and cannabidiol characterized in the 1960s, leading to the discovery of cannabinoid receptors type 1 (CBR) and type 2 (CBR) and the endocannabinoid system (ECS) in the 1990s. The ECS, involving endogenous ligands like 2-arachidonoylglycerol (2-AG) 1.
View Article and Find Full Text PDFAsia Ocean J Nucl Med Biol
January 2025
Department of Radiological Technology, Faculty of Medical Technology, Tokyo, Japan.
Objectives: Brain perfusion single-photon emission computed tomography (SPECT) image quality varies depending on SPECT systems. This study aimed to evaluate the relationship between physical parameters and visual analysis for assessment of the brain SPECT image quality. We conducted our phantom study under various conditions in a multi-center and multi-vendor study.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!