Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: When hemodialysis arteriovenous accesses fail, autogenous options are often limited. Non-autogenous conduit choices include bovine carotid artery xenografts (BCAG) and expanded polytetrafluoroethylene (PTFE), yet their comparative effectiveness in hemodialysis access revision remains largely unknown.
Methods: A cohort study was performed from a prospectively collected institutional database from August 2010 to July 2021. All patients undergoing an arteriovenous access revision with either BCAG or PTFE were followed for up to 3 years from their index access revision. Revision was defined as graft placement to address a specific problem of an existing arteriovenous access while maintaining one or more of the key components of the original access (e.g. inflow, outflow, and cannulation zone). Outcomes were measured starting at the date of the index revision procedure. The primary outcome was loss of secondary patency at 3 years. Secondary outcomes included loss of post-intervention primary patency, rates of recurrent interventions, and 30-day complications. Pooled logistic regression was used to estimate inverse probability weighted marginal structural models for the time-to-event outcomes of interest.
Results: A total of 159 patients were included in the study, and 58% received access revision with BCAG. Common indications for revision included worn out cannulation zones (32%), thrombosis (18%), outflow augmentation (16%), and inflow augmentation (13%). Estimated risk of secondary patency loss at 3 years was lower in the BCAG group (8.6%, 3.9-15.1) compared to the PTFE group (24.8%, 12.4-38.7). Patients receiving BCAG experienced a 60% decreased relative risk of secondary patency loss at 3 years (risk ratio 0.40, 0.14-0.86). Recurrent interventions occurred at similar rates in the BCAG and PTFE groups, with 1.86 (1.31-2.43) and 1.60 (1.07-2.14) interventions at 1 year, respectively (hazard ratio 1.22, 0.74-1.96).
Conclusions: Under the conditions of this contemporary cohort study, use of BCAG in upper extremity hemodialysis access revision decreased access abandonment when compared to PTFE.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/11297298231170654 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!