Background: Deciphering which patients with low-gradient aortic valve disease have severe stenosis can be difficult. We aimed to correlate the postextrasystolic potentiation (PESP) with dobutamine stress echocardiography and multidetector computed tomography in patients with low-gradient aortic valve stenosis.
Methods: Patients with an aortic valve area ≤1 cm and a mean gradient <40 mm Hg were included. Aortic valve stenosis severity was assessed by a core lab with dobutamine stress echocardiography, followed by a multidetector computed tomography aortic valve score if indeterminate. A premature ventricular contraction was induced by intentional catheter contact with the myocardium within the left ventricle. PESP was calculated as a percent change of pre-to-post mean gradient. Multidetector computed tomography was used to measure the aortic valve calcification score, and subsequently, aortic valve calcification density.
Results: Twenty-eight patients (age, 77±10 years; 19 female) were included. Dobutamine stress echocardiography increased mean gradient from baseline of 25±7 mm Hg to 36±11 mm Hg; pre-premature ventricular contraction mean gradient was 25±7 mm Hg and increased to post-premature ventricular contraction mean gradient of 32±10 mm Hg, representing a PESP of 24±11%. A ≥20% in PESP resulted in 100% sensitivity, 77% specificity, 83% positive predictive value, and 100% negative predictive value for diagnosing severe aortic valve stenosis. There was a significant correlation between PESP and projected aortic valve area and aortic valve calcification density (R=-0.64, =0.0003; R=0.057, =0.014, respectively).
Conclusions: In patients with low-gradient aortic valve stenosis, catheter-induced premature ventricular contractions during cardiac catheterization causing ≥20% PESP has a 100% sensitivity for severe aortic valve stenosis. Validation of this 20% cutoff in larger groups with correlation to clinical end points is required.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1161/CIRCINTERVENTIONS.123.012892 | DOI Listing |
BMC Cardiovasc Disord
January 2025
Graduate School of Public Health, St Luke's International University, Tokyo, Japan.
Background: Recent studies revealed an association between small kidney volume and progression of kidney dysfunction in particular settings such as kidney transplantation and transcatheter aortic valve implantation. We hypothesized that kidney volume was associated with the incidence of kidney-related adverse outcomes such as worsening renal function (WRF) in patients with acute heart failure (AHF).
Methods: This study was a single-center retrospective cohort study.
Mol Diagn Ther
January 2025
Department of Medicine and Robarts Research Institute, Schulich School of Medicine and Dentistry, Western University, 4288A-1151 Richmond Street North, London, ON, N6A 5B7, Canada.
Clinical endpoints caused by hyperlipoproteinemia include atherosclerotic cardiovascular disease and acute pancreatitis. Emerging lipid-lowering therapies targeting proprotein convertase subtilisin/kexin 9 (PCSK9), lipoprotein(a), apolipoprotein C-III, and angiopoietin-like protein 3 represent promising advances in the management of patients with hyperlipoproteinemia. These therapies offer novel approaches for lowering pathogenic lipid and lipoprotein species, particularly in patients with serious perturbations who are not adequately controlled with conventional treatments or who are unable to tolerate them.
View Article and Find Full Text PDFEur Heart J Cardiovasc Imaging
January 2025
Department of Cardiology, Istituto Auxologico Italiano, IRCCS, Milan, Italy.
Aims: This study evaluates whether multi-chamber myocardial deformation analysis using speckle tracking echocardiography (STE) can enhance validated current staging systems and improve risk stratification for patients with moderate-to-severe aortic stenosis (AS).
Methods And Results: We reanalyzed 2D, Doppler, and STE data obtained from two cohorts: derivation (654 patients, median age: 82 years; 51% men) and validation (237 patients, median age: 77 years; 55% men) with at least moderate AS (aortic valve area<1.5 cm2).
Eur J Cardiothorac Surg
January 2025
Department of Cardiac Surgery, University Hospital Quironsalud Madrid, Spain.
Objectives: The Ross procedure for aortic regurgitation (AR) and abnormal aortic valve morphologies is associated with an increased risk of autograft dilatation. Autograft support may ameliorate this problem. We analyzed the results for all haemodynamic lesions and the effect of autograft support.
View Article and Find Full Text PDFEur Heart J Case Rep
January 2025
The Second Department of Internal Medicine, University of Toyama, 2630 Sugitani, Toyama, Toyama 930-0194, Japan.
Background: Self-expanding valves used in transcatheter aortic valve implantation (TAVI) are designed to allow recapture and repositioning, facilitating optimal placement and mitigating conduction disturbances and paravalvular leakage. Here, we present a rare case in which the Navitor (Abbott Structural Heart, Santa Clara, CA, USA) could not be recaptured.
Case Summary: An 81-year-old Japanese woman with very severe aortic stenosis and a massively calcified nodule at the non-coronary cusp (NCC) underwent TAVI with a 25 mm Navitor valve.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!