Ablation targets of persistent atrial fibrillation remain poorly understood nowadays: due to structural alterations of the left atrium, isolation of the pulmonary veins alone has proved ineffective. New ablation targets such as the posterior wall, coronary sinus, and left atrial appendage were then sought. A new catheter (QDOT Micro™) has recently been released, which has the potential to increase the safety and efficacy of the procedure: it is connected to a new radiofrequency generator that allows for temperature-controlled ablation by reducing power and increasing irrigation with the increase in tissue temperature and allows to deliver power up to 90 W for few seconds (very high-power short-duration).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10132567PMC
http://dx.doi.org/10.1093/eurheartjsupp/suad050DOI Listing

Publication Analysis

Top Keywords

high-power short-duration
8
persistent atrial
8
atrial fibrillation
8
ablation targets
8
innovative catheter
4
catheter temperature
4
temperature control
4
control high-power
4
ablation
4
short-duration ablation
4

Similar Publications

Introduction: Proactive esophageal cooling reduces injury during radiofrequency (RF) ablation of the left atrium (LA) for the treatment of atrial fibrillation (AF). New catheters are capable of higher wattage settings up to 90 W (very high-power short duration, vHPSD) for 4s. Varying power and duration however does not eliminate the risk of thermal injury.

View Article and Find Full Text PDF

Background: The aim of cavotricuspid isthmus (CTI)-dependent flutter ablation is the bidirectional conduction block of the CTI. Very-high-power short-duration (vHPSD) radiofrequency ablation aims to minimize conductive heating and increase resistive heating to create shallower but wider lesions in a very short time, while reducing the risk of collateral tissue damage. Experimental studies have shown that it produces effective transmural lesions with an equal or better safety profile compared to conventional parameters.

View Article and Find Full Text PDF

Background: The optimal radiofrequency application (RFa) parameters for safe and durable pulmonary vein isolation (PVI) are debated. High-power short-duration (HPSD) has been used as an alternative to conventional power delivery (CPD).

Objectives: This study sought to compare HPSD 70 W/9-10 s (HPSD-70) with CPD 25-40 W in patients undergoing PVI.

View Article and Find Full Text PDF

High Power Short Duration Atrial Fibrillation Ablation: Long-Term Predictors of Success and Recurrence - A Multivariate Analysis.

Arq Bras Cardiol

November 2024

Universidade de São Paulo Faculdade de Medicina de Ribeirão Preto, Ribeirão Preto, SP - Brasil.

Background: Point-by-point ablation with a high-power short-duration (HPSD) technique in atrial fibrillation (AF) ablation is used worldwide. Little data is available with the HPSD and dragging technique (DT).

Objective: To perform a multivariate analysis of clinical and procedural predictors of success and recurrence in HPSD with DT.

View Article and Find Full Text PDF

Introduction: The suitability of high-power short-duration (HPSD) cavo-tricuspid isthmus ablation (CTI-Abl) for electrophysiology (EP) trainees, as well as the underlying mechanisms of its efficacy, remain unknown. The aim of this study was to clarify the efficacy and safety of HPSD CTI-Abl performed by EP trainees and assess lesion characteristics between HPSD and moderate-power long duration (MPLD) ablations.

Methods: Study 1: CTI-Abl was performed by first- to fourth-year EP trainees in consecutive 113 patients (67 ± 11 years, 27.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!