The 3M style 30 intraocular lens was introduced in January 1980 as a closed-loop, uniplanar posterior chamber lens intended for in-the-bag implantation. Between February 13, 1980, and February 28, 1982, 584 of these lenses were implanted by one of us. Except for a few lost to follow-up, these patients have now had a minimum of two years of follow-up under our care. Using a microcomputer-based data-base management system, we have generated graphic and tabular presentations of follow-up, age at time of surgery, best postoperative visual acuity, preoperative and postoperative pathology, and surgical events and complications. A brief discussion of the advantages of the in-the-bag location and the style 30 design characteristics is included. We have been able to profile, compare, and correlate numerous preoperative, operative, and postoperative parameters.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0886-3350(86)80009-8DOI Listing

Publication Analysis

Top Keywords

style intraocular
8
intraocular lens
8
review 584
4
584 style
4
lens implants
4
implants style
4
lens introduced
4
introduced january
4
january 1980
4
1980 closed-loop
4

Similar Publications

Article Synopsis
  • - Glaucoma, particularly normal tension glaucoma (NTG), is a major cause of irreversible blindness and is challenging to diagnose since it occurs with normal intraocular pressures; it often leads to advanced optic nerve damage by the time it’s detected.
  • - Observational studies hint at a potential link between NTG and dyslipidemia (abnormal lipid metabolism), but more research is needed to establish a clear causal connection, which this study aims to investigate.
  • - The research utilizes methods like Mendelian randomization to explore the impact of lipid traits on NTG and seeks to uncover potential therapeutic targets for treatment, contributing to personalized medicine approaches for managing the disease.
View Article and Find Full Text PDF

Prcis: An objective perimetry method provides four 30-2 style reports in 8 minutes. These comprise sensitivity and delay reports for both eyes. A combined report format shows comparable diagnostic power to 2 forms of automated perimetry.

View Article and Find Full Text PDF

Prcis: Wang et al compare an FDA-registered head-mounted smartphone device (PalmScan VF2000) with standard automated perimetry (SAP) in glaucoma patients and find that the head-mounted device may not fully recapitulate SAP testing.

Purpose: This study prospectively compared visual field testing using the PalmScan VF2000 Visual Field Analyzer, a head-mounted smartphone device, with standard automated perimetry (SAP).

Methods: Patients with glaucoma undergoing Humphrey Field Analyzer SAP testing were asked to complete in-office PalmScan testing using a Samsung S5 smartphone in a virtual reality-style headset.

View Article and Find Full Text PDF

Aims: To develop a generative adversarial network (GAN) capable of generating realistic high-resolution anterior segment optical coherence tomography (AS-OCT) images.

Methods: This study included 142 628 AS-OCT B-scans from the American University of Beirut Medical Center. The Style and WAvelet based GAN architecture was trained to generate realistic AS-OCT images and was evaluated through the Fréchet Inception Distance (FID) Score and a blinded assessment by three refractive surgeons who were asked to distinguish between real and generated images.

View Article and Find Full Text PDF

Music during cataract surgery: effect on anxiety.

J Cataract Refract Surg

July 2024

From the Department of Ophthalmology and Visual Sciences, Yale University, New Haven, Connecticut (Rivera, Chow, DeBroff, Diaz); Massachusetts Eye and Ear/Harvard Medical School, Boston, Massachusetts (Linderman); School of Medicine, Yale University, New Haven, Connecticut (Miguez).

Purpose: To determine the effect of playing patient-selected music intraoperatively on patient self-reported anxiety and the amount of sedative administered during cataract surgery.

Setting: Yale New Haven Hospital health system, New Haven, Connecticut.

Design: Prospective, randomized, controlled clinical trial.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!