Copper Organometallic Iodide Arrays for Efficient X-ray Imaging Scintillators.

ACS Cent Sci

Advanced Membranes and Porous Materials Center, Division of Physical Science and Engineering, King Abdullah University of Science and Technology, Thuwal 23955-6900, Kingdom of Saudi Arabia.

Published: April 2023

Lead-free organic metal halide scintillators with low-dimensional electronic structures have demonstrated great potential in X-ray detection and imaging due to their excellent optoelectronic properties. Herein, the zero-dimensional organic copper halide (18-crown-6)Na(HO)CuI (CNCI) which exhibits negligible self-absorption and near-unity green-light emission was successfully deployed into X-ray imaging scintillators with outstanding X-ray sensitivity and imaging resolution. In particular, we fabricated a CNCI/polymer composite scintillator with an ultrahigh light yield of ∼109,000 photons/MeV, representing one of the highest values reported so far for scintillation materials. In addition, an ultralow detection limit of 59.4 nGy/s was achieved, which is approximately 92 times lower than the dosage for a standard medical examination. Moreover, the spatial imaging resolution of the CNCI scintillator was further improved by using a silicon template due to the wave-guiding of light through CNCI-filled pores. The pixelated CNCI-silicon array scintillation screen displays an impressive spatial resolution of 24.8 line pairs per millimeter (lp/mm) compared to the resolution of 16.3 lp/mm for CNCI-polymer film screens, representing the highest resolutions reported so far for organometallic-based X-ray imaging screens. This design represents a new approach to fabricating high-performance X-ray imaging scintillators based on organic metal halides for applications in medical radiography and security screening.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10141593PMC
http://dx.doi.org/10.1021/acscentsci.2c01495DOI Listing

Publication Analysis

Top Keywords

x-ray imaging
16
imaging scintillators
12
organic metal
8
imaging resolution
8
representing highest
8
imaging
7
x-ray
6
copper organometallic
4
organometallic iodide
4
iodide arrays
4

Similar Publications

Right coronary sinus of Valsalva pseudoaneurysm after a motorcycle accident: A case report.

Medicine (Baltimore)

January 2025

Department of Radiology, West China Hospital, Sichuan University, Chengdu, Sichuan, China.

Rationale: Traumatic pseudoaneurysm of the sinus of Valsalva (PSV) is a rare but life-threatening condition, often resulting from blunt chest trauma. Rapid progress and a high risk of rupture highlight the importance of prompt diagnosis and intervention. We present a case of a rare pseudoaneurysm linked to the right coronary sinus after blunt chest trauma.

View Article and Find Full Text PDF

Rationale: Thrombus is the most common occupying lesion in the cardiac chambers, it is often distinguished from cardiac neoplastic occupations. Among them, the most common is cardiac myxoma, whose imaging manifestations are often confused with thrombus. However, the 2 types of lesions have different therapeutic strategies and are both potentially high-risk sources of embolism, so early differentiation between intracardiac thrombus and cardiac tumor is essential.

View Article and Find Full Text PDF

To evaluate the diagnostic accuracy of artificial intelligence (AI) assisted radiologists and standard double-reading in real-world clinical settings for rib fractures (RFs) detection on CT images. This study included 243 consecutive chest trauma patients (mean age, 58.1 years; female, 166) with rib CT scans.

View Article and Find Full Text PDF

Case: A 60-year-old right-hand-dominant woman experienced progressive enlargement of a mass over the index distal interphalangeal (DIP) joint over 5 years, leading to joint destruction and swan neck deformity. Radiography showed arthritis, erosion, and calcific deposition. Surgical intervention included mass excision, synovectomy, and DIP joint arthrodesis.

View Article and Find Full Text PDF

Transcranial Doppler sonography follow-up study in mild vascular cognitive impairment.

PLoS One

January 2025

Department of Medical and Surgical Sciences and Advanced Technologies "G. F. Ingrassia", University of Catania, Catania, Italy.

Background: To date, few data to transcranial Doppler sonography (TCD) are available in patients with mild vascular cognitive impairment (VCI) at risk for vascular or mixed dementia. In a previous study in patients with mild VCI and cerebral small vessels disease, a hemodynamic pattern of cerebral hypoperfusion and enhanced vascular resistance were observed; however, longitudinal data are currently lacking. Here, we perform a clinical, psychopathological, and neurosonological follow-up of patients with VCI in order to monitor any progression and to identify TCD measures to detect it.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!