Background: An empirical selective clamping strategy based on the direction of the arterial branches can lead to failures during partial nephrectomy, even when assisted by three-dimensional virtual models (3DVMs).

Objective: To develop and test new 3DVMs that include kidney perfusion regions and evaluate their intraoperative accuracy in guiding selective clamping and their impact on postoperative renal function.

Design, Setting, And Participants: For patients with a kidney suitable for nephron-sparing surgery, 3DVMs were supplemented with a Voronoi diagram, a Euclidean distance-based mathematical tool, to calculate vascular-dominant regions the kidney.

Surgical Procedure: Robot-assisted partial nephrectomy guided by perfusion-region (PR)-3DVMs.

Measurements: All anatomic information given by the PR-3DVMs was collected. Selective or superselective clamping was planned and performed intraoperatively when feasible under 3DVM assistance. Changes in split renal function (SRF) and estimated renal plasmatic flow (ERPF) were evaluated for 51 patients who underwent baseline and 3-mo postoperative renal scintigraphy.

Results And Limitations: A total of 103 patients were prospectively enrolled. The median number of kidney and tumor perfusion regions were 8 (interquartile range [IQR] 7-10) and 3 (IQR 2-3), respectively. A clampless, selective clamping, and global clamping strategy was applied in eight (7.8%), 79 (76.6%), and 16 (15.5%) cases, respectively, with no differences between planning and surgery in terms of the number or order of arteries clamped or the perfusion regions that underwent ischemia. Among the 51 patients who underwent renal scintigraphy, the mean SRF decreased by 11.3%, 7.7%, and 1.7% after global, selective, and superselective clamping, respectively (p = 0.004). Similar results were obtained for ERPF (18.9%, 9.9%, and 6.0%; p = 0.02). The main limitation is the need for a bioengineer to manually refine the 3DVMs.

Conclusions: Use of mathematical algorithms for 3DVMs allows precise estimation of kidney perfusion regions to maximize the efficacy of selective clamping and minimize renal function impairment.

Patient Summary: Three-dimensional models that include regions of blood flow to the kidney can be used to guide clamping of blood vessels when part of the kidney is being surgically removed. More limited clamping can reduce damage to the remaining portion of the kidney and result in better recovery of kidney function after surgery.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.eururo.2023.04.005DOI Listing

Publication Analysis

Top Keywords

perfusion regions
20
selective clamping
16
clamping strategy
12
partial nephrectomy
12
clamping
10
kidney
9
three-dimensional virtual
8
virtual models
8
robot-assisted partial
8
kidney perfusion
8

Similar Publications

Background And Aim: Pediatric patients undergoing cardiac surgery prior to 1992 in Denmark were at risk of hepatitis C virus (HCV) infection through donor blood used in extracorporeal circulation. HCV screening became possible in donors in 1991, eliminating the risk of iatrogenic infections. No formalized screening has been conducted for patients receiving non-screened blood, potentially leaving some with undetected HCV infection.

View Article and Find Full Text PDF

Solid-state detector single photon emission computed tomography (SPECT) enables the acquisition of dynamic data for calculation of myocardial blood flow (MBF) and myocardial flow reserve (MFR). Here, we report about our experiences on routine clinical use and robustness using Tc-99 m-sestamibi and Tc-99 m-tetrofosmin. 307 patients underwent dynamic list-mode myocardial perfusion imaging (MPI) and standard static MPI for clinical workup of coronary artery disease on a dedicated cardiac SPECT camera.

View Article and Find Full Text PDF

Aim: Newborn infants with critical aortic arch obstruction are often undiagnosed at discharge, despite screening. This study investigated if adding the perfusion index improved early detection.

Methods: We retrospectively studied 38 newborn infants with critical aortic arch obstruction, who were routinely screened in 2014-2019 by 13 Swedish hospitals using pulse oximetry and the perfusion index.

View Article and Find Full Text PDF

Imaging characteristics of brain microstructure and cerebral perfusion in Crohn's disease patients with anxiety: A prospective comparative study.

World J Gastroenterol

January 2025

Department of Radiology, The Affiliated Changzhou Second People's Hospital of Nanjing Medical University, Changzhou Medical Center, Changzhou 213000, Jiangsu Province, China.

Background: Anxiety is a common comorbidity in patients with Crohn's disease (CD). Data on the imaging characteristics of brain microstructure and cerebral perfusion in CD with anxiety are limited.

Aim: To compare the imaging characteristics of brain microstructure and cerebral perfusion among CD patients with or without anxiety and healthy individuals.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!