Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To compare the fracture resistance and failure modes of anterior cantilever resin-bonded fixed partial dentures (RBFPDs) fabricated from high translucency zirconia with different intaglio surface treatments.
Materials And Methods: Sound-extracted canines (N = 50) were randomly divided into five groups (n = 10) to be restored with high translucency zirconia RBFBDs of different intaglio surface treatments. The RBFPD was designed using exocad software and fabricated using a CAM milling machine. The RBFPDs were treated differently: abrasion with 50 µm alumina particles (Group 1); abrasion with 30 µm silica-coated alumina particles (Group 2); abrasion with silica-coated alumina particles (30 µm) and silane application (Group 3); abrasion with silica-coated alumina particles (30 µm) and 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP) primer application (Group 4); abrasion with silica-coated alumina particles (30 µm) and silane, and 10-MDP primer application. All RBFPDs were cemented using dual-cured resin cement. The RBFPDs underwent 6000 thermal cycles with distilled water at 5/55°C for 2 min per cycle and then mechanical cyclic loading with 1200,000 cycles of 50 N at a 1.7 Hz frequency at an angle of 135° to the abutment's long axis. Then, RBFPDs were loaded to fracture using a universal testing machine at 1 mm/min. Maximum fracture forces and failure modes were recorded. Fractured specimens and uncemented specimens were examined using a scanning electron microscope. Data was analyzed using ANOVA and Games-Howell post hoc tests at p < 0.05.
Results: Mean fracture load results showed a statistically significant difference between the research groups (p < 0.0001) and it ranged from 69.78 to 584 N. Group 4 exhibited the highest fracture load mean (p < 0.0001) which was significantly different from all other groups. Group 2 recorded a significantly higher fracture load mean than Group 3 (p = 0.029). Three modes of failure were observed: prosthesis debonding, prosthesis fracture, and abutment fracture.
Conclusions: Abrasion of zirconia surface with 30 µm silica-coated alumina particles and application of 10-MDP primer yielded the highest mean fracture loads of monolithic high translucency zirconia RBFPD. The mode of fracture of the RBFPDs was influenced by the type of surface treatments.