The objective of this work is to review and assess the potential of MgB4O7:Ce,Li to fill in the gaps where the need for a new material for optically stimulated luminescence (OSL) dosimetry has been identified. We offer a critical assessment of the operational properties of MgB4O7:Ce,Li for OSL dosimetry, as reviewed in the literature and complemented by measurements of thermoluminescence spectroscopy, sensitivity, thermal stability, lifetime of the luminescence emission, dose response at high doses (>1000 Gy), fading and bleachability. Overall, compared with Al2O3:C, for example, MgB4O7:Ce,Li shows a comparable OSL signal intensity following exposure to ionizing radiation, a higher saturation limit (ca 7000 Gy) and a shorter luminescence lifetime (31.5 ns). MgB4O7:Ce,Li is, however, not yet an optimum material for OSL dosimetry, as it exhibits anomalous fading and shallow traps. Further optimization is therefore needed, and possible avenues of investigation encompass gaining a better understanding of the roles of the synthesis route and dopants and of the nature of defects.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10142933PMC
http://dx.doi.org/10.3390/ma16083051DOI Listing

Publication Analysis

Top Keywords

osl dosimetry
16
osl
5
addressing current
4
current challenges
4
challenges osl
4
dosimetry
4
dosimetry mgboceli
4
mgboceli state
4
state art
4
art limitations
4

Similar Publications

Implementation of OSL nanoDot dosimetry in different treatment techniques for head and neck cancer.

Radiat Prot Dosimetry

December 2024

Instituto Politécnico Nacional, Escuela Superior de Ingeniería Química e Industrias Extractivas, Edificio 6, Av. Luis Enrique Erro S/N, Unidad Profesional Adolfo López Mateos, 07738 Ciudad de México, México.

In recent decades, technological advances have been made in the field of radiotherapy and with it the emergence of new dosimetric systems for their calibration and commissioning, among other uses. Such is the case of the measurement in the build-up region, where there is no charged-particle equilibrium, which is reflected in the increase in surface dose for patient treatments and potential skin toxicities as a secondary effect. This study utilizes optically stimulated dosemeters (nanoDot) and the radiochromic film (EBT3) to measure skin doses in patients with head and neck cancer who received radiotherapy.

View Article and Find Full Text PDF

This study examines the use of gypsum for radiation dosimetry using Thermoluminescence (TL) and Optically Stimulated Luminescence (OSL) techniques. It is observed that gypsum preserves the information of radiation dose despite the loss of water upon heating in a laboratory. Deconvolution of the thermoluminescence glow curve suggests thermoluminescence glow peaks at 125, 150, 280, 320, and 440 °C.

View Article and Find Full Text PDF

The aim of this study was to evaluate the point doses using a distribution of the size-specific dose estimate (SSDE) from axial CT images of in-house phantoms having diameters from 8 to 40 cm. In-house phantoms made of polyester-resin (PESR) mixed with methyl ethyl ketone peroxide (MEKP) were used. The phantoms were built with different diameter sizes of 8, 16, 24, 32, and 40 cm.

View Article and Find Full Text PDF

Introduction: Radiotherapy is the standard treatment for breast cancer patients after surgery. However, radiotherapy can cause side effects such as dry and moist desquamation of the patient's skin. The dose calculation from a treatment planning system (TPS) might also be inaccurate.

View Article and Find Full Text PDF

The National Cyclotron and PET Centre at Chulabhorn Hospital offers nuclear medicine diagnostic services using state-of-the-art digital PET/CT and PET/MRI machines as well as other related devices. Additionally, the center plays a vital role by having a cyclotron to produce radiopharmaceuticals, which are used both in-house and in other hospitals throughout the country. Despite the center's strict adherence to international standards regarding the use of radioactive substances in patients, there remains a potential risk of radiation exposure for operators, workers, and the public due to radioactive contamination and emissions from unsealed sources.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!