The choice of a ventilator model for a single patient is usually based on parameters such as size (portability), presence or absence of battery and ventilatory modes. However, there are many details within each ventilator model about triggering, pressurisation or autotitration algorithms that may go unnoticed, but may be important or may justify some drawbacks that may occur during their use in individual patients. This review is intended to emphasize these differences. Guidance is also provided on the operation of autotitration algorithms, in which the ventilator is able to take decisions based on a measured or estimated parameter. It is important to know how they work and their potential sources of error. Current evidence on their use is also provided.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10141077 | PMC |
http://dx.doi.org/10.3390/jcm12082942 | DOI Listing |
J Clin Med
April 2023
Servei de Pneumologia, Hospital Universitari Parc Taulí, 08208 Sabadell, Spain.
The choice of a ventilator model for a single patient is usually based on parameters such as size (portability), presence or absence of battery and ventilatory modes. However, there are many details within each ventilator model about triggering, pressurisation or autotitration algorithms that may go unnoticed, but may be important or may justify some drawbacks that may occur during their use in individual patients. This review is intended to emphasize these differences.
View Article and Find Full Text PDFAdv Exp Med Biol
December 2022
Department of Neurology- Baystate Medical Center, University of Massachusetts Medical School-Baystate, Springfield, MA, USA.
Positive airway pressure (PAP) is the primary treatment of sleep-disordered breathing including obstructive sleep apnea, central sleep apnea, and sleep-related hypoventilation. Just as clinicians use pharmacological mechanism of action and pharmacokinetic data to optimize medication therapy for an individual, understanding how PAP works and choosing the right mode and device are critical to optimizing therapy in an individual patient. The first section of this chapter will describe the technology inside PAP devices that is essential for understanding the algorithms used to control the airflow and pressure.
View Article and Find Full Text PDFFront Neurosci
November 2021
Division of Pulmonary and Sleep Medicine, Beth Israel Deaconess Medical Center, Boston, MA, United States.
The interactions of heart rate variability and respiratory rate and tidal volume fluctuations provide key information about normal and abnormal sleep. A set of metrics can be computed by analysis of coupling and coherence of these signals, cardiopulmonary coupling (CPC). There are several forms of CPC, which may provide information about normal sleep physiology, and pathological sleep states ranging from insomnia to sleep apnea and hypertension.
View Article and Find Full Text PDFFront Physiol
December 2020
Division of Pulmonary, Critical Care and Sleep Medicine, Department of Medicine, Beth Israel Deaconess Medical Center, Boston, MA, United States.
A new concept of non-rapid eye movement (NREM) and rapid eye movement (REM) sleep is proposed, that of multi-component integrative states that define stable and unstable sleep, respectively, NREM, NREM REM, and REM. Three complementary data sets are used: obstructive sleep apnea (20), healthy subjects (11), and high loop gain sleep apnea (50). We use polysomnography (PSG) with beat-to-beat blood pressure monitoring, and electrocardiogram (ECG)-derived cardiopulmonary coupling (CPC) analysis to demonstrate a bimodal, rather than graded, characteristic of NREM sleep.
View Article and Find Full Text PDFEur Respir J
September 2020
Lane Fox Respiratory Service, Guy's and St Thomas' NHS Foundation Trust, London, UK.
Background: The optimal noninvasive application of external positive end-expiratory pressure (EPAP) to abolish tidal-breathing expiratory flow limitation (EFL) and minimise intrinsic positive end-expiratory pressure (PEEP) is challenging in COPD patients. We investigated whether auto-titrating EPAP, using the forced oscillation technique (FOT) to detect and abolish EFL, would minimise PEEP, work of breathing and neural respiratory drive (NRD) in patients with severe COPD.
Methods: Patients with COPD with chronic respiratory failure underwent auto-titration of EPAP using a FOT-based algorithm that detected EFL.