A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Relationship between Exercise Test Parameters, Device-Delivered Electric Shock and Adverse Clinical Events in Patients with an Implantable Cardioverter Defibrillator for Primary Prevention. | LitMetric

(1) Background: Receiving the first internal electric shock is a turning point for patients with an implantable cardioverter defibrillator (ICD) for primary prevention. However, no study has investigated whether patients who receive a first device-delivered electric shock have a poor prognosis even at the time of ICD implantation. (2) Methods: We retrospectively identified 55 patients with ischemic (n = 31) or dilated (n = 24) cardiomyopathy who underwent ICD implantation for primary prevention with exercise test at the time of implantation. We recorded baseline characteristics, exercise test parameters, and clinical events. (3) Results: After a median follow-up of 5 years, we observed an association between an appropriate device-delivered electric shock, the occurrence of death or heart transplant, and the occurrence of the composite endpoint. There was also a significant relation between a VE/VCO slope >35 and the occurrence of the composite endpoint. Conversely, there was no significant association between negative outcomes on the exercise test and the occurrence of a device-delivered electric shock. (4) Conclusions: The exercise test performed at the time of ICD implantation do not predict the occurrence of device-delivered electric shock. The exercise test and the first electric shock are two independent markers of poor prognosis.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10143101PMC
http://dx.doi.org/10.3390/jpm13040589DOI Listing

Publication Analysis

Top Keywords

electric shock
28
exercise test
24
device-delivered electric
20
primary prevention
12
icd implantation
12
test parameters
8
clinical events
8
patients implantable
8
implantable cardioverter
8
cardioverter defibrillator
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!