A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Biomechanical Comparison of Conventional Plate and the C-Nail System for the Treatment of Displaced Intra-Articular Calcaneal Fractures: A Finite Element Analysis. | LitMetric

The C-Nail system is a novel intramedullary fixation method for displaced intra-articular calcaneal fractures. The aim of this study was to evaluate the biomechanical performance of the C-Nail system and compare it with conventional plate fixation for the treatment of displaced intra-articular calcaneal fractures using finite element analysis. The geometry of a Sanders type-IIB fracture was constructed using the computer-aided design software Ansys SpaceClaim. The C-Nail system (Medin, Nové Mesto n. Morave, Czech Republic) and the calcaneal locking plate (Auxein Inc., 35 Doral, Florida) and screws were designed according to the manufacturer specifications. Vertical loading of 350 N and 700 N were applied to the subtalar joint surfaces to simulate partial weight bearing and full weight bearing. Construct stiffness, total deformation, and von Mises stress were assessed. The maximum stress on the C-Nail system was lower compared with the plate (110 MPa vs. 360 MPa). At the bone level the stress was found to have higher values in the case of the plate compared to the C-Nail system. The study suggests that the C-Nail system can provide sufficient stability, making it a viable option for the treatment of displaced intra-articular calcaneal fractures.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10141664PMC
http://dx.doi.org/10.3390/jpm13040587DOI Listing

Publication Analysis

Top Keywords

c-nail system
28
displaced intra-articular
16
intra-articular calcaneal
16
calcaneal fractures
16
treatment displaced
12
conventional plate
8
fractures finite
8
finite element
8
element analysis
8
weight bearing
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!