Purpose: The purpose of this study was to investigate the benefit of aortic volumes compared to diameters or cross-sectional areas on three-dimensional (3D) magnetic resonance imaging (MRI) in discriminating between patients with dilated aorta and matched controls.
Materials And Methods: Sixty-two patients (47 men and 15 women; median age, 66 years; age range: 33-86 years) with tricuspid aortic valve and ascending thoracic aorta aneurysm (TAV-ATAA) and 43 patients (35 men and 8 women; median age, 51 years; age range: 17-76 years) with bicuspid aortic valve and dilated ascending aorta (BAV) were studied. One group of 54 controls matched for age and sex to patients with TAV-ATAA (39 men and 15 women; median age, 68 years; age range: 33-81 years) and one group of 42 controls matched for age and sex to patients with BAV (34 men and 8 women; median age, 50 years; age range: 17-77 years) were identified. All participants underwent 3D MRI, used for 3D-segmentation for measuring aortic length, maximal diameter, maximal cross-sectional area (CSA) and volume for the ascending aorta.
Results: An increase in ascending aorta volume (TAV-ATAA: +107%; BAV: +171% vs. controls; P < 0.001) was found, which was three times greater than the increase in diameter (TAV-ATAA: +29%; BAV: +40% vs. controls; P < 0.001). In differentiating patients with TAV-ATAA from their controls, the indexed ascending aorta volume showed better performances (AUC, 0.935 [95% confidence interval (CI): 0.882-0.989]; accuracy, 88.7% [95% CI: 82.9-94.5]) than indexed ascending aorta length (P < 0.001), indexed ascending aorta maximal diameter (P = 0.003) and indexed ascending aorta maximal CSA (P = 0.03). In differentiating patients with BAV from matched controls, indexed ascending aorta volume showed significantly better performances performance (AUC, 0.908 [95% CI: 0.829-0.987]; accuracy, 88.0% [95% CI: 80.9-95.0]) than indexed ascending aorta length (P = 0.02) and not different from indexed ascending aorta maximal diameter (P = 0.07) or from indexed ascending aorta maximal CSA (P = 0.27) CONCLUSION: Aortic volume measured by 3D-MRI integrates both elongation and luminal dilatation, resulting in greater classification performance than maximal diameter and length in differentiating patients with dilated ascending aorta or aneurysm from controls.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.diii.2023.04.004 | DOI Listing |
J Physiol
January 2025
Center for Developmental Health, Oregon Health & Science University, Portland, OR, USA.
Robust preclinical models of asymmetric ventricular loading in late gestation reflecting conditions such as hypoplastic left heart syndrome are lacking. We characterized the morphometry and microvascular function of the hypoplastic left ventricle (LV) and remaining right ventricle (RV) in a sham-controlled late gestation fetal lamb model of impaired left ventricular inflow (ILVI). Singleton fetuses were instrumented at ∼120 days gestational age (dGA; term is ∼147 days) with vascular catheters, an aortic flow probe and a deflated left atrial balloon.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Engineering Mechanics, KTH Royal Institute of Technology, Stockholm, Sweden.
Aneurysm rupture is a life-threatening event, yet its underlying mechanisms remain largely unclear. This study investigated the fracture properties of the thoracic aneurysmatic aorta (TAA) using the symmetry-constraint Compact Tension (symconCT) test and compared results to native and enzymatic-treated porcine aortas' tests. With age, the aortic stiffness increased, and tissues ruptured at lower fracture energy [Formula: see text].
View Article and Find Full Text PDFJ Med Genet
January 2025
Center of Medical Genetics, University of Antwerp and Antwerp University Hospital, Antwerp, Belgium.
Background: Individuals harbouring pathogenic variants are at risk for aneurysms/dissections throughout the arterial tree. Based on prior reports of sex differences in thoracic aortic aneurysm/dissection, we investigated the sexual dimorphism for vascular events in variant-harbouring patients.
Methods: We analysed two large pedigrees comprising 84 individuals segregating pathogenic missense variants affecting the same p.
J Invasive Cardiol
December 2024
Division of Cardiology, Stony Brook University Hospital, Stony Brook, New York.
A A Pract
January 2025
Department of Anesthesiology, University of Kansas Medical Center, Kansas City, Kansas.
Transcatheter aortic valve replacement (TAVR) is a common treatment for severe aortic stenosis (AS), but it carries the risk of severe complications, including device embolization. We present a case of a TAVR valve embolization into the left ventricular outflow tract (LVOT), diagnosed with transesophageal echocardiography (TEE) shortly after device deployment. The dislodged valve was successfully retrieved from the LVOT into the aorta, flattened, and stabilized with a thoracic endovascular aneurysm repair (TEVAR) stent, enabling the successful implantation of a new TAVR valve.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!