The importance of the inert environment in the transmission of pathogens has been reassessed in recent years. To reduce cross-contamination, new biocidal materials used in high touch surfaces (e.g., stair railings, door handles) have been developed. However, their impact on skin remains poorly described. The present study aimed to evaluate the antibacterial properties and the risk of skin irritation of two materials based on hard-anodized aluminum (AA) impregnated with quaternary ammonium compound solutions (QAC#1 or QAC#2). The QAC#1 or QAC#2 solutions vary in composition, QAC#2 being free of dioctyl dimethyl ammonium chloride (Dio-DAC) and octyl decyl dimethyl ammonium chloride (ODDAC). Unlike AA used as a control, both AA-QAC#1 and AA-QAC#2 had excellent and rapid antibacterial efficacy, killing 99.9 % of Staphylococcus aureus and Escherichia coli bacteria, in 15 s and 1 min, respectively. The impregnation solutions (QAC#1 and QAC#2) did not show any skin sensitizing effect on transformed human keratinocytes. Nevertheless, these solutions as well as the materials (AA-QAC#1, AA-QAC#2), and the liquid extracts derived from them, induced a very rapid cytotoxicity on L929 murine fibroblasts (>70 % after 1 h of contact) as shown by LDH, MTS and neutral red assays. This cytotoxicity can be explained by the fast QACs release occurring when AA-QAC#1 and AA-QAC#2 were immersed in aqueous medium. To overcome the limitation of assays based on liquid condition, an in vitro skin irritation assay on reconstructed human epidermis (RHE) was developed. The effect of the materials upon their direct contact with the epidermis grown at the liquid-air interface was determined by evaluating tissue viability and quantifying interleukin-1 alpha (IL-1α) which is released in skin during injury or infection. AA-QAC#1 induced a significant decrease in RHE viability, close to OECD and ISO 10993-10 acceptability thresholds and enhanced the pro-inflammatory IL-1α secretion compared with AA-QAC#2. Finally, these results were corroborated by in vivo assays on mice using erythema and edema visual scores, histological observations, and epidermal thickness measurement. AA had no effect on the skin, while a stronger irritation was induced by AA-QAC#1 compared with AA-QAC#2. Hence, these materials were classified as moderate and slight irritants, respectively. In summary, this study revealed that AA-QAC#2 without Dio-DAC and ODDAC could be a great candidate for high touch surface applications, showing an extremely effective and rapid bactericidal activity, without inducing adverse effects for skin tissue.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.bioadv.2023.213433 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!