A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Procedural and one-year outcomes of the BASILICA technique in Europe: the multicentre EURO-BASILICA registry. | LitMetric

Background: The real-world outcomes of the use of the BASILICA (Bioprosthetic or Native Aortic Scallop Intentional Laceration to Prevent Iatrogenic Coronary Artery Obstruction) transcatheter technique in Europe have not been described.

Aims: We sought to evaluate the procedural and one-year outcomes of BASILICA in patients at high risk for coronary artery obstruction (CAO) undergoing transcatheter aortic valve implantation (TAVI) in a multicentre European registry (EURO-BASILICA).

Methods: Seventy-six patients undergoing BASILICA and TAVI at ten European centres were included. Eighty-five leaflets were identified as targets for BASILICA due to high risk for CAO. The updated Valve Academic Research Consortium 3 (VARC-3) definitions were used to determine prespecified endpoints of technical and procedural success and adverse events up to one year.

Results: Treated aortic valves included native (5.3%), surgical bioprosthetic (92.1%) and transcatheter valves (2.6%). Double BASILICA (for both left and right coronary cusps) was performed in 11.8% of patients. Technical success with BASILICA was achieved in 97.7% and resulted in freedom from any target leaflet-related CAO in 90.6% with a low rate of complete CAO (2.4%). Target leaflet-related CAO occurred significantly more often in older and stentless bioprosthetic valves and with higher implantation levels of transcatheter heart valves. Procedural success was 88.2%, and freedom from VARC-3-defined early safety endpoints was 79.0%. One-year survival was 84.2%; 90.5% of patients were in New York Heart Association Functional Class I/II.

Conclusions: EURO-BASILICA is the first multicentre study evaluating the BASILICA technique in Europe. The technique appeared feasible and effective in preventing TAVI-induced CAO, and one-year clinical outcomes were favourable. The residual risk for CAO requires further study.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10397663PMC
http://dx.doi.org/10.4244/EIJ-D-22-00960DOI Listing

Publication Analysis

Top Keywords

outcomes basilica
12
technique europe
12
procedural one-year
8
one-year outcomes
8
basilica
8
basilica technique
8
coronary artery
8
artery obstruction
8
high risk
8
risk cao
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!