A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Wear of Titanium Implant Platforms with Different Abutment Connections and Abutment Materials: A Pilot Study. | LitMetric

Wear of Titanium Implant Platforms with Different Abutment Connections and Abutment Materials: A Pilot Study.

J Funct Biomater

Faculdade de Medicina Dentária, Universidade de Lisboa, 1600-277 Lisbon, Portugal.

Published: March 2023

The most commonly used material in dental implants and their abutments is titanium. Zirconia is a more aesthetic alternative to titanium abutments; however, it is much harder. There are concerns that zirconia could damage the surface of the implant over time, especially in less stable connections. The aim was to evaluate the wear of implants with different platforms connected to titanium and zirconia abutments. A total of six implants were evaluated, two of each connection type: external hexagon, tri-channel, and conical connections (n = 2). Half of the implants were connected to zirconia abutments, and the other half to titanium abutments (n = 3). The implants were then cyclically loaded. The implant platforms were evaluated by digital superimposing micro CT files and calculating the area of the loss surface (wear). In all the implants, a statistically significant loss of the surface area ( = 0.028) was observed when comparing the area before and after cyclic loading. The average lost surface area was 0.38 mm with titanium abutments and 0.41 mm with zirconia abutments. The average lost surface area was 0.41 mm with the external hexagon, 0.38 mm with the tri-channel, and 0.40 mm with the conical connection. In conclusion, the cyclic loads induced implant wear. However, neither the type of abutment ( = 0.700) nor the connection ( = 0.718) influenced the amount of surface area lost.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10146395PMC
http://dx.doi.org/10.3390/jfb14040178DOI Listing

Publication Analysis

Top Keywords

surface area
16
titanium abutments
12
zirconia abutments
12
implant platforms
8
titanium zirconia
8
wear implants
8
external hexagon
8
loss surface
8
average lost
8
lost surface
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!