There is a growing interest in innovative products for eyebrow hair loss treatment with fewer adverse effects. Nevertheless, a fundamental formulation aspect of preventing the fragile skin from the ocular region from being irritated is that the formulations remain restricted to the application region and do not run off. Consequently, the methods and protocols in drug delivery scientific research must be adapted to fulfill such performance analysis demand. Thus, this work aimed to propose a novel protocol to evaluate the in vitro performance of a topical gel formulation with a reduced runoff for minoxidil (MXS) delivery to eyebrows. MXS was formulated with 16% poloxamer 407 (PLX) and 0.4% of hydroxypropyl methylcellulose (HPMC). The sol/gel transition temperature, viscosity at 25 °C, and formulation runoff distance on the skin were evaluated to characterize the formulation. The release profile and skin permeation were evaluated in Franz vertical diffusion cells for 12 h and compared to a control formulation (4% PLX and 0.7% HPMC). Then, the formulation's performance at promoting minoxidil skin penetration with minimum runoff was evaluated in a vertical custom-made permeation template (divided into three areas: superior, middle, and inferior). The MXS release profile from the test formulation was comparable to that from the MXS solution and the control formulation. There was also no difference in the MXS amount that penetrated the skin in the permeation experiments in Franz diffusion cells using the different formulations ( > 0.05). However, the test formulation demonstrated a localized MXS delivery at the application site in the vertical permeation experiment. In conclusion, the proposed protocol could differentiate the test formulation from the control, attesting to its better performance in efficiently delivering MXS to the site of interest (middle third of application). The vertical protocol can be easily employed to evaluate other gels with a drip-free appeal.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10137639 | PMC |
http://dx.doi.org/10.3390/gels9040269 | DOI Listing |
Clin Drug Investig
January 2025
Department of Medicine, Biostatistics, Epidemiology, and Informatics, University of Pennsylvania, Perelman School of Medicine, 423 Guardian Drive, Philadelphia, PA, 19104, USA.
Purpose: The REDUCE-IT randomized trial demonstrated a cardiovascular benefit of icosapent ethyl (IPE) but also raised potential safety signals for atrial fibrillation (AF) and serious bleeding. We aimed to evaluate the real-world safety of IPE versus mixed omega-3 polyunsaturated fatty acid (OM-3) formulations.
Methods: This retrospective active comparator new-user cohort study compared rates of new-onset AF and major bleeding (MB) among adult new users of IPE versus OM-3 in 2020-2024 US Veterans Affairs data.
Expert Opin Drug Deliv
January 2025
Advanced Drug Delivery, Pharmaceutical Sciences, R&D, AstraZeneca, Macclesfield, UK.
Introduction: mRNA therapeutics were a niche area in drug development before COVIDvaccines. Now they are used in vaccine development, for non-viral therapeuticgenome editing, chimericantigen receptor T (CAR T) celltherapies and protein replacement. mRNAis large, charged, and easily degraded by nucleases.
View Article and Find Full Text PDFJ Clin Med
January 2025
Department of Operative Gynecology, Federal State Budget Institution V. I. Kulakov Research Centre for Obstetrics, Gynecology, and Perinatology, Ministry of Health of the Russian Federation, 117997 Moscow, Russia.
: The diagnosis and treatment of endometriosis should be based on the best available evidence. Emphasising the risk of bias, the pyramid of evidence has the double-blind, randomised controlled trial and its meta-analyses on top. After the grading of all evidence by a group of experts, clinical guidelines are formulated using well-defined rules.
View Article and Find Full Text PDFJ Clin Med
December 2024
Department of Ophthalmology, Chonnam National University Medical School and Hospital, Gwangju 61469, Republic of Korea.
Sensitivity to ocular irritation varies among individuals, being influenced by clinical, subjective, and biochemical factors. This study aimed to evaluate individual variability in ocular irritation sensitivity, focusing on clinical parameters, pain perception, and tear neuromediator profiles. Sixty female participants aged 20-40 were classified into high-sensitivity and low-sensitivity groups based on their response to an irritant (Tween20).
View Article and Find Full Text PDFSensors (Basel)
December 2024
Xi'an Aerospace Chemical Propulsion Co., Ltd., Xi'an 710089, China.
In this paper, we propose an optimal parking path planning method based on numerical solving, which leverages the concept of the distance between convex sets. The obstacle avoidance constraints were transformed into continuous, smooth nonlinear constraints using the Lagrange dual function. This approach enables the determination of a globally optimal parking path while satisfying vehicular kinematic constraints.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!