To evaluate the effect of insertion depth, bone type, and implant diameter on the primary stability of short implants. Commercial dental implants with different lengths (6 and 8 mm; BLX, Straumann) were inserted into artificial bone specimens of good and poor quality at three different depth positions: equicrestal, 1-mm subcrestal, and 2-mm subcrestal. Insertion torque values were recorded spontaneously during the implant procedure. Both maximum insertion torque values (MITVs) and final insertion torque values (FITVs) were recorded. Subsequently, Periotest values (PTVs) and implant stability quotients (ISQs) were measured for all specimens. The mean MITVs of all groups ranged from 31.8 to 46.2 Ncm. However, the mean FITVs of all groups ranged from 8.8 to 29 Ncm. Torque values decreased significantly when the implants were inserted into their final positions. When insertion depth was increased, the PTV and ISQ decreased. Long implants and implants inserted into good-quality bone yielded greater primary stability, and bone quality appeared to have a greater effect on primary stability. When 6-mm short implants are inserted in a subcrestal position, low primary stability may be yielded, particularly in poor-quality bone.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.11607/jomi.9769 | DOI Listing |
Clin Exp Nephrol
January 2025
Department of Nephrology, Yueyang Hospital of Integrated Traditional Chinese and Western Medicine, Shanghai University of Traditional Chinese Medicine, Shanghai, China.
Background: Previous studies have suggested a potential role of estrogen in the pathophysiology of chronic kidney disease (CKD); however, the association and causality between estrogen and kidney function remain unclear.
Methods: The cross-sectional correlation between serum estradiol concentration and estimated glomerular filtration rate (eGFR) and urinary albumin-to-creatinine ratio (ACR) was analyzed using data from the National Health and Nutrition Examination Survey 2013-2016. Causality was tested using mutual bidirectional Mendelian randomization (MR) approaches based on six large-scale GWAS studies.
Tissue Eng Regen Med
January 2025
Department of Oral and Maxillofacial Surgery, Section of Dentistry, Seoul National University Bundang Hospital, 172 Dolma-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, 13620, Republic of Korea.
Background: Traditionally, dental implants require a healing period of 4 to 9 months for osseointegration, with longer recovery times considered when bone grafting is needed. This retrospective study evaluates the clinical efficacy of demineralized dentin matrix (DDM) combined with recombinant human bone morphogenetic protein-2 (rhBMP-2) during dental implant placement to expedite the osseointegration period for early loading.
Methods: Thirty patients (17 male, 13 female; mean age 55.
J Neurochem
January 2025
Core Facility Small Animal MRI, Ulm University, Ulm, Germany.
Proton magnetic resonance spectroscopy (MRS) offers a non-invasive, repeatable, and reproducible method for in vivo metabolite profiling of the brain and other tissues. However, metabolite fingerprinting by MRS requires high signal-to-noise ratios for accurate metabolite quantification, which has traditionally been limited to large volumes of interest, compromising spatial fidelity. In this study, we introduce a new optimized pipeline that combines LASER MRS acquisition at 11.
View Article and Find Full Text PDFLife Sci Alliance
April 2025
https://ror.org/0040axw97 Yunnan Key Laboratory of Cell Metabolism and Diseases, State Key Laboratory for Conservation and Utilization of Bio-Resources in Yunnan, Center for Life Sciences, School of Life Sciences, Yunnan University, Kunming, China
NME7 (nucleoside diphosphate kinase 7), a lesser studied member of the non-metastatic expressed (NME) family, has been reported as a potential subunit of the γ-tubulin ring complex (γTuRC). However, its role in the cilium assembly and function remains unclear. Our research demonstrated that NME7 is located at the centrosome, including at the spindle poles during metaphase and at the basal bodies during cilium assembly.
View Article and Find Full Text PDFFacial Plast Surg
January 2025
Department of Rhinology and Facial Plastic Surgery, Royal National ENT and Eastman Dental Hospitals, University College London Hospitals NHS Foundation Trust, London, United Kingdom.
Optimal results in complex nasal reconstruction, particularly in the context of post-traumatic and revision septorhinoplasty, often require the use of cartilage grafts to provide additional structural support to the nose. While autologous costal cartilage (ACC) has been traditionally used, this can be limited by donor site morbidity, increased operative time, and in some cases, lack of suitable cartilage for grafting. There has been a trend towards using irradiated homologous costal cartilage (IHCC) as an alternative source of graft material.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!