A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@remsenmedia.com&api_key=81853a771c3a3a2c6b2553a65bc33b056f08&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Ecodesign and Operational Strategies to Reduce the Carbon Footprint of MRI for Energy Cost Savings. | LitMetric

Ecodesign and Operational Strategies to Reduce the Carbon Footprint of MRI for Energy Cost Savings.

Radiology

From the Department of Radiology and Biomedical Imaging, University of California-San Francisco, 505 Parnassus Ave, San Francisco, CA 94143 (S.A.W., A.E.B., A.J.M., C.P.H.); Siemens Healthineers, Erlangen, Germany (R.K.); Siemens Smart Infrastructure, Fremont, Calif (V.L.); Siemens Smart Infrastructure, Austin, Tex (J.F.); and Siemens Healthineers, Malvern, Pa (C.E., V.D.).

Published: May 2023

Background Radiology is a major contributor to health care's climate footprint due to energy-intensive devices, particularly MRI, which uses the most energy. Purpose To determine the energy, cost, and carbon savings that could be achieved through different scanner power management strategies. Materials and Methods In this retrospective evaluation, four outpatient MRI scanners from three vendors were individually equipped with power meters (1-Hz sampling rate). Power measurement logs were extracted for 39 days. Data were segmented into off, idle, prepared-to-scan, scan, or power-save modes for each scanner. Energy, cost (assuming a mean cost of $0.14 per kilowatt hour), and carbon savings were calculated for the lowest scanner activity modes. Data were summarized using descriptive statistics and 95% CIs. Results Projected annual energy consumption per scanner ranged from 82.7 to 171.1 MW-hours, with 72%-91% defined as nonproductive. Power draws for each mode were measured as 6.4 kW ± 0.1 (SD; power-save mode), 7.3 kW ± 0.6 to 9.7 kW ± 0.2 (off), 9.5 kW ± 0.9 to 14.5 kW ± 0.5 (idle), 17.3 kW ± 0.5 to 25.6 kW ± 0.6 (prepared-to-scan mode), and 28.6 kW ± 8.6 to 48.3 kW ± 11.8 (scan mode). Switching MRI units from idle to off mode for 12 hours overnight reduced power consumption by 25%-33%, translating to a potential annual savings of 12.3-21.0 MW-hours, $1717-$2943, and 8.7-14.9 metric tons of carbon dioxide (CO) equivalent (MTCOeq). The power-save mode further reduced consumption by 22%-28% compared with off mode, potentially saving an additional 8.8-11.4 MW-hours, $1226-$1594, and 6.2-8.1 MTCOeq per year for 12 hours overnight. Implementation of a power-save mode for 12 hours overnight in all outpatient MRI units in the United States could save U.S. health care 58 863.2-76 288.2 MW-hours, $8.2-$10.7 million, and 41 606.4-54 088.3 MTCOeq. Conclusion Powering down MRI units made radiology departments more energy efficient and showed substantial sustainability and cost benefits. © RSNA, 2023 See also the article by Vosshenrich and Heye in this issue.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.230441DOI Listing

Publication Analysis

Top Keywords

energy cost
12
power-save mode
12
mri units
12
hours overnight
12
mri energy
8
carbon savings
8
outpatient mri
8
mode
8
mode hours
8
mri
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!