Background: With the introduction of prostate specific membrane antigen (PSMA) PET/CT, the detection rate of prostate cancer metastases has improved significantly, both for primary staging and for biochemical recurrence. EANM/SNMMI guidelines recommend a 60 min time interval between [ Ga]Ga-PSMA administration and acquisition.
Purpose: This study evaluates the possibility of a shorter time interval by investigating the dynamic change in image quality measures.
Method: We retrospectively analyzed 10 consecutive prostate cancer patients who underwent a dynamic whole body [ Ga]Ga-PSMA-11 PET/CT of 75 min from skull vertex to mid-thigh using Siemens FlowMotion. PET images were acquired directly after injection of 1.5 MBq/kg [ Ga]Ga-PSMA-11. Image quality measures included lesion maximum standardized uptake value corrected for lean body mass (SUL ), tumor-to-background ratio (TBR), and contrast-to-noise ratio (CNR). Quantitative analysis of image quality in dynamic PET was performed using PMOD (version 4.2). Regions of interest (ROIs), drawn included different types of prostate lesions (primary tumor, lymph nodes, and bone metastasis), organ tissue (liver, spleen, lacrimal gland, submandibular gland, parotid gland, urinary bladder, kidneys blood pool [ascending aorta], left ventricle), bone tissue (4th lumbar vertebral body [L4]) and muscle tissue (gluteus maximus). To further investigate image quality four 10 min multi-frame reconstructions with clinical parameters were made at different post-injection times (15, 30, 45, and 60 min). A nuclear medicine physician performed a blinded lesion detectability evaluation on these multi-frame reconstructions for different prostate cancer lesions.
Results: Six primary prostate tumors in seven patients with prostate in situ, 13 lymph node metastases in six patients and up to 12 bone metastases in three patients were found. The different prostate lesion types (lymph nodes metastases, bone metastases, and primary prostate tumor) all show an increase in average SUL , TBR, and CNR over time during the scan. The normalized average SUL , TBR, and CNR of the combined prostate lesions at 15, 30, and 45 min post-injection scans were all significant p < 0.05 lower from the 60 min post-injection [ Ga]Ga-PSMA-11 PET/CT (9.5 ± 4.5, 12.7 ± 6.2, and 41.8 ± 24.5, respectively). At patient level, the reader concluded the same regarding the presence/absence of primary prostate cancer recurrence, lymph node metastases, and/or bone metastases on all <60 min post-injection [ Ga]Ga-PSMA-11 PET/CT's in comparison to the reference scan (60 min post-injection). At lesion level, all bone metastases seen on the reference scan were also seen on all <60 min post-injection [ Ga]Ga-PSMA-11 PET/CT's but there were some lymph nodes (n = 2) metastases missed on the 15, 30, and 45 min post-injection scans. One lymph node metastasis on both the 15 and 30 min post-injection [ Ga]Ga-PSMA-11 PET/CT's was missed and one lymph node metastasis was missed, only on the 45 min post-injection [ Ga]Ga-PSMA-11 PET/CT.
Conclusion: Shorter post-injection times (15, 30, and 45 min) compared to the recommended post-injection time of 60 min are not optimal. However, the impact of a shorter time interval of 45 min instead of 60 min between [ Ga]Ga-PSMA-11 administration and the start of PET/CT acquisition on both image quality (SUL , TBR, and CNR) and lesion detection, while significant, is small.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/mp.16429 | DOI Listing |
Gynecol Oncol
January 2025
Division of Gynecologic Oncology, St. Luke's University Health Network, Bethlehem, PA, United States of America.
Objective: We sought to determine the cost-effectiveness (CE) of lymph node dissection (LND) at the time of hysterectomy for endometrial intraepithelial neoplasia (EIN).
Methods: A decision analytic model was created to evaluate the strategies of routine full LND, sentinel lymph node dissection (SNLD), SNLD without advancing to full LND in the event of non-mapping, and full LND based on Mayo Criteria, versus no LND. Patients in the no LND group and those in the SLND group without advancement to full LND in the event of non-mapping who were found to have EC on final pathology and suspicious post-operative imaging underwent full LND.
J Osteopath Med
January 2025
Arizona College of Osteopathic Medicine, Midwestern University, Glendale, AZ, USA.
Context: Point-of-care ultrasound (POCUS) has diverse applications across various clinical specialties, serving as an adjunct to clinical findings and as a tool for increasing the quality of patient care. Owing to its multifunctionality, a growing number of medical schools are increasingly incorporating POCUS training into their curriculum, some offering hands-on training during the first 2 years of didactics and others utilizing a longitudinal exposure model integrated into all 4 years of medical school education. Midwestern University Arizona College of Osteopathic Medicine (MWU-AZCOM) adopted a 4-year longitudinal approach to include POCUS education in 2017.
View Article and Find Full Text PDFEClinicalMedicine
December 2024
Nottingham Digestive Diseases Centre (NDDC), Translational Medical Sciences, School of Medicine, University of Nottingham, NG7 2UH, UK.
Background: Despite the availability of various pharmacological and behavioural interventions, alcohol-related mortality is rising. This systematic review aimed to critically evaluate the existing literature on the association between glucagon-like peptide-1 receptor agonists use (GLP-1 RAs) and alcohol consumption.
Methods: Electronic searches were conducted on Ovid Medline, EMBASE, PsycINFO, clintrials.
Whole-body PET imaging is often hindered by respiratory motion during acquisition, causing significant degradation in the quality of reconstructed activity images. An additional challenge in PET/CT imaging arises from the respiratory phase mismatch between CT-based attenuation correction and PET acquisition, leading to attenuation artifacts. To address these issues, we propose two new, purely data-driven methods for the joint estimation of activity, attenuation, and motion in respiratory self-gated TOF PET.
View Article and Find Full Text PDFPurpose: Reliable image quality assessment is crucial for evaluating new motion correction methods for magnetic resonance imaging. In this work, we compare the performance of commonly used reference-based and reference-free image quality metrics on a unique dataset with real motion artifacts. We further analyze the image quality metrics' robustness to typical pre-processing techniques.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!