A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 143

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 994
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3134
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Assessment of Nit-Occlud atrial septal defect occluder device healing process using micro-computed tomography imaging. | LitMetric

AI Article Synopsis

  • After implanting a cardiac occluder in sheep, the study investigated the healing process and tissue coverage of the device over one to three months.
  • Micro-computed tomography (micro-CT) imaging revealed that while the left-side disk of the device showed complete coverage, the right-side disk had incomplete coverage in most cases, increasing the risk of complications.
  • The research indicated that micro-CT is a valuable tool for assessing tissue reactions post-implantation, highlighting its potential utility in monitoring patients and preventing issues like thrombosis and endocarditis.

Article Abstract

After percutaneous implantation of a cardiac occluder, a complex healing process leads to the device coverage within several months. An incomplete device coverage increases the risk of device related complications such as thrombosis or endocarditis. We aimed to assess the device coverage process of atrial septal defect (ASD) occluders in a chronic sheep model using micro-computed tomography (micro-CT). After percutaneous creation of an ASD, 8 ewes were implanted with a 16-mm Nit-Occlud ASD-R occluder (PFM medical, Cologne, Germany) and were followed for 1 month (N = 3) and 3 months (N = 5). After heart explant, the device coverage was assessed using micro-CT (resolution of 41.7 μm) and was compared to histological analysis. The micro-CT image reconstruction was performed in 2D and 3D allowing measurement of the coverage thickness and surface for each device. Macroscopic assessment of devices showed that the coverage was complete for the left-side disk in all cases. Yet incomplete coverage of the right-side disk was observed in 5 of the 8 cases. 2D and 3D micro-CT analysis allowed an accurate evaluation of device coverage of each disk and was overall well correlated to histology sections. Surface calculation from micro-CT images of the 8 cases showed that the median surface of coverage was 93±8% for the left-side disk and 55±31% for the right-side disk. The assessment of tissue reactions, including endothelialisation, after implantation of an ASD occluder can rely on in vitro micro-CT analysis. The translation to clinical practice is challenging but the potential for individual follow-up is shown, to avoid thrombotic or infective complications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10124873PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0284471PLOS

Publication Analysis

Top Keywords

device coverage
20
coverage
9
atrial septal
8
septal defect
8
device
8
healing process
8
micro-computed tomography
8
left-side disk
8
right-side disk
8
micro-ct analysis
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!