We compared three cell isolation and two proteomic sample preparation methods for single-cell and near-single-cell analysis. Whole blood was used to quantify hemoglobin (Hb) and glycated-Hb (gly-Hb) in erythrocytes using targeted mass spectrometry and stable isotope-labeled standard peptides. Each method differed in cell isolation and sample preparation as follows: 1) FACS and automated preparation in one-pot for trace samples (autoPOTS); 2) limited dilution via microscopy and a novel rapid one-pot sample preparation method that circumvented the need for the solid-phase extraction, low-volume liquid handling instrumentation and humidified incubation chamber; and 3) CellenONE-based cell isolation and the same one-pot sample preparation method used for limited dilution. Only the CellenONE device routinely isolated single-cells from which Hb was measured to be 540-660 amol per red blood cell (RBC), which was comparable to the calculated SI reference range for mean corpuscular hemoglobin (390-540 amol/RBC). FACSAria sorter and limited dilution could routinely isolate single-digit cell numbers, to reliably quantify CMV-Hb heterogeneity. Finally, we observed that repeated measures, using 5-25 RBCs obtained from = 10 blood donors, could be used as an alternative and more efficient strategy than single RBC analysis to measure protein heterogeneity, which revealed multimodal distribution, unique for each individual.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10243106PMC
http://dx.doi.org/10.1021/acs.jproteome.2c00429DOI Listing

Publication Analysis

Top Keywords

sample preparation
20
cell isolation
12
limited dilution
12
preparation methods
8
one-pot sample
8
preparation method
8
sample
5
cell
5
preparation
5
methods targeted
4

Similar Publications

Molecularly imprinted electrochemical sensor to sensitively detect tetramethylpyrazine in Baijiu.

Analyst

January 2025

Jiangsu Province Hi-Tech Key Laboratory for Biomedical Research, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China.

Tetramethylpyrazine (TMP) is a compound known for its natural health benefits, but current detection methods for TMP are overly expensive and time-consuming. In this study, we developed functional materials with TMP molecular recognition properties using molecularly imprinted technology. As TMP does not produce electrochemical signals in the detection potential range, hexacyanoferrate was selected as a redox probe, combined with the highly conductive polymer PEDOT:PSS to enhance electrode conductivity.

View Article and Find Full Text PDF

Background: Oral cancer screening programs can aid in the early identification of potentially malignant oral lesions. The objective of the present study was to evaluate the effectiveness of the Oral Rub and Rinse (ORR) technique as an oral cancer screening tool and to test its potential in detecting genetic alterations in exfoliated cells obtained through ORR.

Methods: The screening programs were conducted in rural Dakshina Kannada and Udupi districts in Karnataka.

View Article and Find Full Text PDF

The development of chiral organic materials with strong non-reciprocal chiroptical features may have major implications for cutting-edge technological applications. In this work, a new synthesized chiral 1,4-diketo-3,6-dithienylpyrrolo[3,4-]pyrrole dye, bearing two ()-3,7-dimethyl-1-octyl alkyl chains on the lactam moieties and functionalized with two lateral 9-anthracenyl π-conjugated units, exhibited strong non-reciprocal chiroptical properties in thin films, with some important differences between samples prepared by drop casting and spin coating. A detailed study was performed to unravel the intimate structure-property relationship, involving computational analysis, different microscopy techniques and synchrotron radiation Mueller matrix polarimetry imaging (SR-MMP) investigation.

View Article and Find Full Text PDF

Comparing Sectional and Total Dentin Bond Strengths of Three Endodontic Sealers after Using the Single-cone Obturation Technique: An Study.

J Contemp Dent Pract

October 2024

College of Dentistry, Ajman University, Ajman P.O. Box 346, United Arab Emirates; Department of Endodontic, Faculty of Dentistry, Mansoura University, Egypt, Orcid: https://orcid.org/0000-0003-3391-5306.

Aim: This study aimed to investigate and compare the total and sectional bond strengths of three endodontic sealers when used with the single-cone obturation technique.

Materials And Methods: Forty-five human maxillary central incisors were prepared and divided into three groups according to the type of endodontic sealer: Group I (Gutta-percha/AH Plus Jet), group II (Gutta-percha/GuttaFlow 2), and group III (RealSeal/RealSeal SE). All canals were filled with the single-cone technique.

View Article and Find Full Text PDF

Background/purpose: Osseointegration potential is greatly depended on the interaction between bone cells and dental implant surface. Since zirconia ceramic has a bioinert surface, functionalization of the surface with an organic compound allylamine was conducted to overcome its drawback of minimal interaction with the surrounding bone.

Materials And Methods: The zirconia surface was initially treated with argon glow discharge plasma (GDP), then combined with amine plasma at three different conditions of 50-W, 75-W and 85-W, to prepare the final samples.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!