Background: We compared T1- and T2-weighted signal intensities of liver-specific (gadoxetate, gadobenate) and non-specific (gadoterate) gadolinium contrast agents (CAs) in a bile phantom.

Methods: In a phantom study, gadoxetate, gadobenate, and gadoterate were diluted in saline, blood, and bile at different concentrations (0, 0.25, 0.5. 1, 2.5, 5, 10, and 25 mM) and imaged in a 3-T magnetic resonance imaging (MRI) system using T1- and T2-weighted sequences. The maximum signal intensities of CAs were compared for each sequence separately and across all T1-weighted sequences using one-way ANOVA.

Results: Using T1-weighted sequences, CA concentration-dependent signal intensity increase was followed by decrease due to T2* effects. Comparing CAs for each sequence in bile yielded higher maximum signal intensities with gadobenate than gadoxetate and gadoterate using T1-weighted spin-echo (p < 0.010), multiecho gradient- and spin-echo (p < 0.001), and T1-weighted high-resolution isotropic volume excitation (eTHRIVE) sequences (p < 0.010). Comparing across all T1-weighted sequences in the bile phantom, gadobenate imaged using T1-weighted turbo field-echo (TFE) sequence showed the highest signal intensity, significantly higher than that using other CAs agents or sequences (p < 0.004) except for gadobenate and gadoxetate evaluated with three-dimensional multiecho fast field-echo (3D-mFFE) and gadoxetate with T1-weighted TFE sequence (p > 0.141). Signal reduction with CA concentration-dependent decrease was observed on T2-weighted images.

Conclusion: In this bile phantom study of gadolinium-based CA, gadobenate and gadoxetate showed high signal intensity with T1-weighted TFE and 3D-mFFE sequences, which supports their potential utility for contrast-enhanced hepatobiliary MRI.

Key Points: • Contrast-enhanced magnetic resonance (MR) cholangiography depends on contrast agent type, kinetics, and concentration in bile, • We compared signal intensities of three contrast agents in a bile phantom study. • Gadobenate, gadoxetate, and gadoterate demonstrated different signal intensities at identical concentrations. • Gadoxetate and gadobenate showed high signal intensities on T1-weighted MR sequences.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10126166PMC
http://dx.doi.org/10.1186/s41747-023-00331-2DOI Listing

Publication Analysis

Top Keywords

signal intensities
12
contrast agents
8
saline blood
8
blood bile
8
phantom study
8
t1- t2-weighted
8
gadoxetate gadobenate
8
maximum signal
8
t1-weighted sequences
8
comparison gadolinium-based
4

Similar Publications

Nanoscale polarization transient gratings.

Nat Commun

December 2024

Elettra - Sincrotrone Trieste S.C.p.A., S.S. 14 km 163.5 in Area Science Park, 34149, Trieste, Italy.

Light manipulation at the nanoscale is essential both for fundamental science and modern technology. The quest to shorter lengthscales, however, requires the use of light wavelengths beyond the visible. In particular, in the extreme ultraviolet regime these manipulation capabilities are hampered by the lack of efficient optics, especially for polarization control.

View Article and Find Full Text PDF

Hypochlorous acid(HClO)/hypochlorite ion (ClO-) is a highly reactive oxygen species (ROS) that play a crucial role in various biological processes. In this paper, a "turn-on" phosphorescent probe (Ir-TPP) for detecting ClO- in mitochondria was designed and synthesized. In solution, Ir-TPP is minimal emission due to rapid isomerization of C=N-OH as an efficient non-radiative decay process.

View Article and Find Full Text PDF

Given that non-equilibrium molecular motion in thermal gradients is influenced by both solute and solvent, the application of spectroscopic methods that probe each component in a binary mixture can provide insights into the molecular mechanisms of thermal diffusion for a large class of systems. In the present work, we use an all-optical setup whereby near-infrared excitation of the solvent leads to a steady-state thermal gradient in solution, followed by characterization of the non-equilibrium system with electronic spectroscopy, imaging, and intensity. Using rhodamine B in water as a case study, we perform measurements as a function of solute concentration, temperature, wavelength, time, near-infrared laser power, visible excitation wavelength, and isotope effect.

View Article and Find Full Text PDF

Traditional beat frequency quartz-enhanced photoacoustic spectroscopy (BF-QEPAS) are limited by short energy accumulation times and the necessity of a decay period, leading to weaker signals and longer measurement cycles. Herein, we present a novel optomechanical energy-enhanced (OEE-) BF-QEPAS technique for fast and sensitive gas sensing. Our approach employs periodic pulse-width modulation (PWM) of the laser signal with an optimized duty cycle, maintaining the quartz tuning fork's (QTF) output at a stable steady-state level by applying stimulus signals at each half-period and allowing free vibration in alternate half-periods to minimize energy dissipation.

View Article and Find Full Text PDF

A Rare Case of Nasal myiasis following Kidney Transplantation.

Arch Razi Inst

June 2024

Nephrology and Urology Research Center, Clinical Science Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran.

In this case report, we present a 63-year-old man with a history of diabetes mellitus and kidney transplantation who was diagnosed with nasal myiasis. The patient presented with symptoms of nasal myiasis infestation, including epistaxis, nasal obstruction, nasal discharge, and the presence of larvae. The patient had risk factors for poor wound healing, such as hyperglycemia, and the presence of diabetes mellitus, hypertension, and kidney transplantation indicated the presence of predisposing factors for myiasis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!