AI Article Synopsis

  • Current transcatheter therapies for tricuspid valve replacement differ in design, fixation, and anchoring methods.!* -
  • The report discusses the use of the Intrepid device, which replaces the tricuspid valve by anchoring it through oversizing at the annular perimeter.!* -
  • This case specifically addresses severe tricuspid regurgitation caused by leaflet interference from a ventricular septal defect occluder.!*

Article Abstract

Current transcatheter tricuspid therapies vary by design with different mechanisms of fixation, anchoring, and therapy. This is the first published report of transfemoral tricuspid valve replacement with the Intrepid device, a valve designed to anchor from annular perimeter oversizing, to treat torrential tricuspid regurgitation from leaflet impingement secondary to a ventricular septal defect occluder. ().

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10119480PMC
http://dx.doi.org/10.1016/j.jaccas.2023.101773DOI Listing

Publication Analysis

Top Keywords

transcatheter tricuspid
8
tricuspid valve replacement
4
valve replacement novel
4
novel self-expanding
4
self-expanding valve
4
valve secure
4
secure fixation
4
fixation insecure
4
insecure anatomy
4
anatomy current
4