Tissue-engineered cartilage constructs have shown promise to treat focal cartilage defects in multiple clinical studies. Notably, products in clinical use or in late-stage clinical trials often utilize porous collagen scaffolds to provide mechanical support and attachment sites for chondrocytes. Under loading, both the local mechanical responses of collagen scaffolds and the corresponding cellular outcomes are poorly understood, despite their wide use. As such, the architecture of collagen scaffolds varies significantly among tissue-engineered cartilage products, but the effects of such architectures on construct mechanics and cell viability are not well understood. This study investigated the effects of local mechanical responses of collagen scaffolds on chondrocyte viability in tissue-engineered cartilage constructs. We utilized fast confocal microscopy combined with a strain mapping technique to analyze the architecture-dependent instabilities under quasi-static loading and subsequent chondrocyte death in honeycomb and sponge scaffolds. More specifically, we compared the isotropic and the orthotropic planes for each type of collagen scaffold. Under compression, both planes exhibited elastic, buckled, and densified deformation modes. In both loading directions, cell death was minimal in regions that experienced elastic deformation mode and a trend of increase in buckled mode. More interestingly, we saw a significant increase in cell death in densified mode. Overall, this study suggests that local instabilities are directly correlated to chondrocyte death in tissue-engineered cartilage constructs, highlighting the importance of understanding the architecture-dependent local mechanical responses under loading.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jbiomech.2023.111591 | DOI Listing |
Pharmaceutics
December 2024
Sports Medicine Division, Institute of Orthopedics and Traumatology, Hospital das Clínicas HCFMUSP, Faculdade de Medicina, Universidade de São Paulo, São Paulo 05403-010, SP, Brazil.
Background/objectives: Cartilage injuries and osteoarthritis are prevalent public health problems, due to their disabling nature and economic impact. Mesenchymal stromal cells (MSCs) isolated from different tissues have the immunomodulatory capacity to regulate local joint environment. This translational study aims to compare cartilage restoration from MSCs from the synovial membrane (SM) and dental pulp (DP) by a tissue-engineered construct with Good Manufacturing Practices.
View Article and Find Full Text PDFJ Biomed Mater Res B Appl Biomater
January 2025
Department of Mechanical Engineering, Cleveland State University, Cleveland, Ohio, USA.
Osteoarthritis (OA) is a prevalent joint disorder that is characterized by the degeneration of articular cartilage in synovial joints. Most of the current treatment options for this disorder tend to focus on symptom management rather than addressing the underlying progression of the disease. Cartilage tissue engineering has emerged as a promising approach to address the limitations of current OA treatments, aiming to regenerate cartilage and restore the natural function of affected joints.
View Article and Find Full Text PDFBiofabrication
January 2025
Tissue Engineering + Biofabrication Laboratory, Department of Health Sciences & Technology, ETH Zürich, Otto-Stern-Weg 7, 8093 Zürich, Switzerland.
Tissue-engineered grafts that mimic articular cartilage show promise for treating cartilage injuries. However, engineering cartilage cell-based therapies to match zonal architecture and biochemical composition remains challenging. Decellularized articular cartilage extracellular matrix (dECM) has gained attention for its chondro-inductive properties, yet dECM-based bioinks have limitations in mechanical stability and printability.
View Article and Find Full Text PDFJ Mater Chem B
January 2025
National Engineering Research Center for Biomaterials, Sichuan University, Chengdu 610064, China.
Microtia profoundly affects patients' appearance and psychological well-being. Tissue engineering ear cartilage scaffolds have emerged as the most promising solution for ear reconstruction. However, constructing tissue engineering ear cartilage scaffolds requires multiple passaging of chondrocytes, resulting in their dedifferentiation and loss of their special phenotypes and functions.
View Article and Find Full Text PDFBiomaterials
December 2024
School of Medicine, Nankai University, Tianjin, 300071, PR China; Institute of Orthopedics, The First Medical Center, Chinese PLA General Hospital, Beijing Key Lab of Regenerative Medicine in Orthopedics, Key Laboratory of Musculoskeletal Trauma & War Injuries PLA, No. 28 Fuxing Road, Haidian District, Beijing, 100853, PR China; National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation, Beijing, 100853, PR China. Electronic address:
The mechanical mismatch of scaffold matrix-mesenchymal stem cells (MSCs) has been a longstanding issue in the clinical application of MSC-based therapy for articular cartilage (AC) regeneration. Existing tissue-engineered scaffolds underestimate the importance of the natural chondrocyte pericellular matrix (PCM). Here, we reveal the temporal and spatial characteristics of collagen distribution around the chondrocytes.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!