Impact of prior cryptococcal antigen screening on in-hospital mortality in cryptococcal meningitis or fungaemia among HIV-seropositive individuals in South Africa: a cross-sectional observational study.

Clin Microbiol Infect

Centre for Healthcare-Associated Infections, Antimicrobial Resistance and Mycoses, National Institute for Communicable Diseases, A Division of the National Health Laboratory Service, Johannesburg, South Africa; School of Pathology, Faculty of Health Sciences, University of the Witwatersrand, Johannesburg, South Africa; Institute of Infection and Immunity, St George's University of London, London, UK; Medical Research Council Centre for Medical Mycology, University of Exeter, Exeter, UK; Division of Medical Microbiology, Faculty of Health Sciences, University of Cape Town, Cape Town, South Africa. Electronic address:

Published: August 2023

Objectives: We investigated whether patients with cryptococcal meningitis (CM) or fungaemia detected through South Africa's laboratory cryptococcal antigen (CrAg) screening programme had better outcomes than those presenting directly to the hospital.

Methods: We compared 14-day in-hospital case-fatality ratios of HIV-seropositive individuals with CD4 counts below 100 cells/μL and laboratory-confirmed CM/fungaemia from 2017-2021, with or without evidence of a positive blood CrAg test within 14 days prior to diagnosis. We evaluated whether the impact of prior CrAg screening on mortality varied according to the study period (pre-COVID-19: before March 2020 vs. COVID-19: after March 2020).

Results: Overall, 24.5% (830/3390) of patients had a prior positive CrAg test within 14 days of diagnosis. CrAg-screened patients were less likely to have an altered mental status at baseline than non-CrAg-screened patients (38.1% [296/776] vs. 42.6% [1010/2372], p = 0.03), and had a lower crude 14-day case-fatality ratio (24.7% [205/830] vs. 28.3% [724/2560]; OR, 0.83 [95% CI, 0.69-0.99]; p = 0.045). Previous CrAg screening was associated with a greater reduction in the crude 14-day mortality during the COVID-19 period (OR, 0.64 [0.47-0.87]; p = 0.005) compared with before (OR, 0.95 [0.76-1.19]; p = 0.68). After adjustment, previous CrAg screening within 14 days was associated with increased survival only during the COVID-19 period (adjusted OR, 0.70 [0.51-0.96]; p = 0.03).

Discussion: Previous CrAg screening was associated with a survival benefit in patients hospitalized with CM/fungaemia during the COVID-19 period, with fewer patients having an altered mental status at baseline, suggesting that these patients may have been diagnosed with cryptococcosis earlier.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cmi.2023.04.016DOI Listing

Publication Analysis

Top Keywords

crag screening
20
previous crag
12
covid-19 period
12
impact prior
8
cryptococcal antigen
8
cryptococcal meningitis
8
meningitis fungaemia
8
hiv-seropositive individuals
8
crag test
8
test 14 days
8

Similar Publications

Cryptococcal meningitis is a major cause of death in HIV/AIDS patients due to the existence of in the central nervous system. Our objective was to evaluate the prevalence of Cryptococcus antigenuria in a population of HIV-infected patients in Libreville, Gabon. : This study was conducted from April to October 2021 at the Infectious Diseases ward of the Centre Hospitalier Universitaire de Libreville.

View Article and Find Full Text PDF

Comparing the Performance of Two Cryptococcal Antigen Detection Tests: Chemiluminescence vs Colloidal Gold Methods.

Infect Drug Resist

December 2024

Centre of Laboratory Medicine, Zhejiang Provincial People's Hospital, People's Hospital of Hangzhou Medical College, Hangzhou, Zhejiang, People's Republic of China.

Objective: To compare the performance of a new chemiluminescence method with that of the traditional colloidal gold method for cryptococcal antigen (CrAg) detection.

Methods: Cryptococcosis is a global invasive mycosis associated with significant morbidity and mortality. Cryptococcal antigen (CrAg) testing from serum and cerebrospinal fluid (CSF) has been regarded as the gold standard for early diagnosis.

View Article and Find Full Text PDF

Objective: This study aimed to assess the efficacy of innovative Chemiluminescence Immunoassay (CLIA) in testing Cryptococcal Antigen (CrAg) across two medical centers, employing the FDA-approved CrAg Lateral Flow Assay (LFA) by IMMY as a reference standard.

Methods: The study encompassed patients diagnosed with cryptococcosis at West China Hospital of Sichuan University (HX) between July 2022 and May 2023, and Suzhou Fifth People's Hospital (SZ) from September 2020 to September 2023. All specimens underwent simultaneous detection using the LFA (IMMY, Norman, USA) and CLIA (Chuanglan, Suzhou, China).

View Article and Find Full Text PDF

Cryptococcosis predominantly affects immunocompromised individuals, particularly those with advanced HIV disease, with meningitis being the most severe form and linked to high mortality. Diagnosis typically relies on rapid Cryptococcus antigen (CrAg) testing, and antigen titer quantification helps in early detection and assessing disease severity. However, conventional titer methods are often more expensive than qualitative antigen detection.

View Article and Find Full Text PDF

Background: Nigeria adapted the WHO package of care for Advanced HIV Disease (AHD) in 2020. The package includes CD4 + cell count testing to identify People Living with HIV (PLHIV) with AHD, screening and treatment of opportunistic infections, rapid antiretrovirals (ART) initiation, and intensive adherence follow-up. The national program adopted a phased approach in the rollout of the AHD package of care to learn lessons from a few representative health facilities before scaling up across the country.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!