A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Outcomes of Ceramic-On-Ceramic Bearing Total Hip Arthroplasty: A Minimum 10-Year Follow-Up Study. | LitMetric

Background: Although the fourth generation of ceramics has demonstrated excellent clinical results 5 to 6 years postoperatively, concerns over ceramic fracture and squeaking persist and longer-term follow-up (minimum 10 years) studies are warranted. Our study aimed to evaluate the minimum 10-year clinical outcomes and bearing-specific complications of ceramic-on-ceramic (CoC) total hip arthroplasties.

Methods: We retrospectively evaluated all patients who underwent primary delta CoC total hip arthroplasty in our institution between January 2004 and February 2013. Demographics, surgical techniques, complications, patient-reported outcomes, and radiographic outcomes were collected and analyzed. For continuous variables, the comparison between groups was conducted using a one-way analysis of variance. Of all 235 patients included in the study, 70.5% were women (190 hips). The mean follow-up period was 12 years (range, 10 to 18). The femoral head sizes of 28- mm, 32 mm, and 36 mm were used in 50, 26, and 197 cases, respectively. Mean acetabular inclination and anteversion angles were 39.2 ± 7.1° and 14.9 ± 3.5°.

Results: There were 5 hips revised at a mean 4.6 years (range, 0.1 to 7.1). One revision was squeaking-related. Squeaking was also reported by 8 other patients, but did not require revision. Other reasons for revision were early infection in 2 cases, stem loosening in 1 case, and stem fracture in 2 cases. The survival analysis for any causes for revision as an endpoint was 96.7% (95% confidence interval 0.313%-2.57%).

Conclusion: We report excellent mean 12-year follow-up results regarding the complications and survivorship of the fourth generation CoC bearings.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arth.2023.04.018DOI Listing

Publication Analysis

Top Keywords

total hip
12
hip arthroplasty
8
minimum 10-year
8
fourth generation
8
coc total
8
years range
8
outcomes
4
outcomes ceramic-on-ceramic
4
ceramic-on-ceramic bearing
4
bearing total
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!