Micro-Quartz Crystal Tuning Fork-Based Photodetector Array for Trace Gas Detection.

Anal Chem

Laser Spectroscopy and Sensing Laboratory, Anhui University, Hefei 230601, China.

Published: May 2023

In this paper, a micro-quartz crystal tuning fork (M-QCTF) was first demonstrated for developing a low-cost, highly sensitive quartz tuning fork photodetector array for spectroscopic applications. A gas sensing system based on the M-QCTF photodetector and highly sensitive wavelength modulation spectroscopy was developed. Typically, an atmospheric greenhouse gas methane (CH) molecule was selected as the target analyte for evaluating the M-QCTF and standard commercial QCTF detectivity. The results indicate that the M-QCTF photodetector exhibits ∼3.3 times sensitivity enhancement compared to the standard commercial QCTF. The long-term stability was evaluated by using the Allan deviation analysis method; a minimum detection limit of 1.2 ppm was achieved with an optimal integration time of 85 s, and the corresponding normalized noise equivalent absorption coefficient was calculated to be 4.45 × 10 cm W/√Hz. Finally, a two-M-QCTF array detection scheme was experimentally demonstrated, and a signal-to-noise ratio enhancement factor of more than 1.7 times compared to that achieved using a single M-QCTF photodetector was realized, which proves a great potential for developing ultra-sensitive quartz tuning fork photodetector arrays for various applications.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.3c00318DOI Listing

Publication Analysis

Top Keywords

tuning fork
12
m-qctf photodetector
12
micro-quartz crystal
8
crystal tuning
8
photodetector array
8
highly sensitive
8
quartz tuning
8
fork photodetector
8
standard commercial
8
commercial qctf
8

Similar Publications

Improved T-shaped quartz tuning fork with isosceles-trapezoidal grooves optimized for quartz-enhanced photoacoustic spectroscopy.

Photoacoustics

February 2025

Key Laboratory of Micro-Inertial Instrument and Advanced Navigation Technology Ministry of Education, School of Instrument Science and Engineering, Southeast University, Nanjing 210096, China.

The quartz tuning fork (QTF) being the acoustic-electrical conversion element for quartz-enhanced photoacoustic spectroscopy (QEPAS) system directly affects the detection sensitivity. However, the low electromechanical conversion efficiency characteristic of standard QTF limits the further enhancement of the system. Therefore, the optimized design for QTF is becoming an important approach to improve the performance of QEPAS.

View Article and Find Full Text PDF

Open-closed single-tube on-beam tuning-fork-enhanced fiber-optic photoacoustic spectroscopy.

Photoacoustics

October 2024

Wuhan National Laboratory for Optoelectronics (WNLO) and National Engineering Research Center of Next Generation Internet Access-system, School of Optical and Electronic Information, Huazhong University of Science and Technology, Wuhan 430074, China.

A proof-of-concept on-beam tuning-fork-enhanced photoacoustic sensor based on an open-closed single-tube acoustic-microresonator (AmR) was proposed and investigated for the first time, to the best of our knowledge. Due to the high acoustic amplification effect, the open-closed AmR improved the detection sensitivity by 54 times with respect to the bare tuning fork (TF). Compared to traditional dual-tube/single-tube on-beam spectrophone configuration, the developed approach significantly facilitates the laser beam alignment and reduces the sensor size and gas consumption.

View Article and Find Full Text PDF

In this paper, a highly sensitive methane (CH) sensor based on light-induced thermoelastic spectroscopy (LITES) and a T-shaped quartz tuning fork (QTF) with hydrogen (H) and helium (He) enhancement techniques are reported for the first time. The low resonant frequency self-designed T-shaped QTF was exploited for improving the energy accumulation time. H and He were utilized as surrounding gases for the T-shaped QTF to minimize energy loss, thereby enhancing the sensitivity of the LITES sensor.

View Article and Find Full Text PDF

We present an all-fiber-based laser gas analyzer (LGA) employing quartz-enhanced photoacoustic spectroscopy (QEPAS) and a side-polished fiber (SPF). The LGA comprises a custom quartz tuning fork (QTF) with 0.8 mm prong spacing, two acoustic micro-resonators (mR) located on either side of the prong spacing, and a single-mode fiber containing a 17 mm polished section passing through both mRs and QTF.

View Article and Find Full Text PDF

Diagnostic Accuracy of Screening Tests for Diabetic Peripheral Neuropathy: An Umbrella Review.

J Diabetes Res

December 2024

Neuroscience Research Group (NeURos), Neurovitae-UR Neuroscience Center, Institute of Translational Medicine (IMT), School of Medicine and Health Sciences, Universidad del Rosario, Bogotá 111221, Colombia.

Peripheral neuropathy is a common cause of morbidity in diabetes. Despite recent advancements in early diagnosis methods, there is a need for practical, highly sensitive, and cost-effective screening methods in clinical practice. This study summarizes evidence from systematic reviews and meta-analyses on the diagnostic accuracy of validated screening methods for diabetic peripheral neuropathy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!