Performance-enhanced clogging-free viscous sheath constriction impedance flow cytometry.

Lab Chip

State Key Laboratory of Precision Measurement Technology and Instrument, Department of Precision Instrument, Tsinghua University, Beijing, P. R. China.

Published: May 2023

As a label-free and high-throughput single cell analysis platform, impedance flow cytometry (IFC) suffers from clogging caused by a narrow microchannel as mechanical constriction (MC). Current sheath constriction (SC) solutions lack systematic evaluation of the performance and proper guidelines for the sheath fluid. Herein, we hypothesize that the viscosity of the non-conductive liquid is the key to the performance of SC, and propose to employ non-conductive viscous sheath flow in SC to unlock the tradeoff between sensitivity and throughput, while ensuring measurement accuracy. By placing MC and SC in series in the same microfluidic chip, we established an evaluation platform to prove the hypothesis. Through modeling analysis and experiments, we confirmed the accuracy (error < 1.60% ± 4.71%) of SC w.r.t. MC, and demonstrated that viscous non-conductive PEG solution achieved an improved sensitivity (7.92×) and signal-to-noise ratio (1.42×) in impedance measurement, with the accuracy maintained and free of clogging. Viscous SC IFC also shows satisfactory ability to distinguish different types of cancer cells and different subtypes of human breast cancer cells. It is envisioned that viscous SC IFC paves the way for IFC to be really usable in practice with clogging-free, accurate, and sensitive performance.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d3lc00178dDOI Listing

Publication Analysis

Top Keywords

viscous sheath
8
sheath constriction
8
impedance flow
8
flow cytometry
8
measurement accuracy
8
viscous ifc
8
cancer cells
8
viscous
5
performance-enhanced clogging-free
4
clogging-free viscous
4

Similar Publications

Technologies that describe the biomechanics of the eye are of emerging importance in glaucoma and keratoconus. A defect in the wall of the eye would be expected to affect biomechanics, resulting in the dispersion of mechanical energy and more viscous rather than elastic behaviour. Here, a mildly myopic man in his 50s was noted to have a deep conduit beside the right optic disc which appeared to pass posteriorly to the optic nerve sheath or orbit.

View Article and Find Full Text PDF

High-Speed Electrospinning of Ethyl Cellulose Nanofibers via Taylor Cone Optimization.

ACS Appl Eng Mater

October 2024

Department of Chemistry and Biochemistry, Rowan University, Glassboro, New Jersey 08028, United States.

Ethyl cellulose (EC) is one of the most widely used cellulose derivatives. Nevertheless, challenges such as the formation of beaded fibers, low yield, and nonporous internal structure persist in electrospinning, limiting functional improvements and industrial applications. This study invented a groundbreaking high-speed electrospinning technique through sheath liquid assistance to optimize the Taylor cone, dramatically enhancing the yield, morphology, and formation of porous structures of EC nanofibers beyond what has been seen in the literature to date.

View Article and Find Full Text PDF

Siphon is an effective method to transfer liquid from a higher to a lower level, which has many applications in hygienic design, clinical apparatus, and hydraulic engineering. Traditional operation requires energy to overcome gravity and establish flow in a closed system. Achieving sustainable high flux siphon drainage without energy input remains a challenge due to viscous dissipation.

View Article and Find Full Text PDF

Performance-enhanced clogging-free viscous sheath constriction impedance flow cytometry.

Lab Chip

May 2023

State Key Laboratory of Precision Measurement Technology and Instrument, Department of Precision Instrument, Tsinghua University, Beijing, P. R. China.

As a label-free and high-throughput single cell analysis platform, impedance flow cytometry (IFC) suffers from clogging caused by a narrow microchannel as mechanical constriction (MC). Current sheath constriction (SC) solutions lack systematic evaluation of the performance and proper guidelines for the sheath fluid. Herein, we hypothesize that the viscosity of the non-conductive liquid is the key to the performance of SC, and propose to employ non-conductive viscous sheath flow in SC to unlock the tradeoff between sensitivity and throughput, while ensuring measurement accuracy.

View Article and Find Full Text PDF

Objectives: Tract embolization has been performed to prevent bleeding after trans-organ puncture. This study evaluated clinical outcomes of tract embolization using a gel-like radiopaque material comprising two sheets of gelatin sponge and 3 mL of contrast agent, and experimentally confirmed its viscosity and hemostatic efficacy.

Methods: Three study phases were planned.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!