A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Biomechanical evaluation of interlocking nail and locking compression plating for stabilization of ovine critical-sized segmental tibia defects. | LitMetric

Background: Segmental large volume bone loss resulting from fracture or osseous neoplasia is a major challenge to orthopedic surgeons and there is an ongoing quest to identify treatments that optimize healing. To advance treatment, large animal translational models-such as the ovine critical-sized tibia defect model-are instrumental for testing of novel scaffolds for bone regeneration. However, little standardization in the implants utilized for defect stabilization has been determined and current commercially available implants may be inadequate to replicate the strength of the native tibia. We hypothesize that a 10-mm interlocking nail (ILN) would be stiffer in axial, bending, and torsional loading than its 8-mm counterpart and would be stiffer in axial and torsional loading compared to a 4.5-mm broad locking compression plate (LCP).

Methods: Tibias were harvested from 24 ovine hind limbs from skeletally mature ewes euthanized for reasons unrelated to this study and were randomized to treatment group. An comparison of a novel 10-mm angle-stable non-tapered ILN was compared to a commercially available 8-mm angle-stable tapered ILN and a broad LCP in an ovine critical-sized (5-cm) tibia defect model. Axial stiffness, torsional stiffness, and bending stiffness were determined in control intact tibia and tibial constructs in the three treatment groups. Following implantation, radiography was performed in all limbs and tibia length and cortical and medullary cavity diameter were measured. Comparisons between groups were assessed with a one-way analysis of variance. Significance was set at P<0.05.

Results: The 10-mm ILN in tibia containing a 5-cm ostectomy gap most closely replicated the structural properties of intact tibia compared with other constructs. The 10-mm ILN had significantly stronger torsional (P<0.001) and bending (P=0.002) stiffness than the 8-mm ILN, and was significantly stronger than the LCP in axial (P=0.04) and torsional (P=0.01) stiffness.

Conclusions: A 10-mm ILN used to stabilize an ovine critically-sized tibia defect most closely mimicked the structural properties of the intact tibia when compared to a 8-mm ILN or broad LCP. Further testing will aid in determining which stabilization method is best suited for testing of novel tissue engineering and bone healing studies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10113068PMC
http://dx.doi.org/10.21037/atm-22-4886DOI Listing

Publication Analysis

Top Keywords

ovine critical-sized
12
interlocking nail
8
locking compression
8
tibia defect
8
stiffer axial
8
torsional loading
8
tibia
6
biomechanical evaluation
4
evaluation interlocking
4
nail locking
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!