Forehead monitoring of heart rate in neonatal intensive care.

Front Physiol

Optics and Photonics Research Group, Faculty of Engineering, University of Nottingham, Nottingham, United Kingdom.

Published: April 2023

Heart rate is an extremely important physiological parameter to measure in critically unwell infants, as it is the main physiological marker that changes in response to a change in infant condition. Heart rate is routinely measured peripherally on a limb with a pulse oximeter. However, when infants are critically unwell, the blood supply to these peripheries is reduced in preference for central perfusion of vital organs such as the brain and heart. Measurement of heart rate with a reflection mode photoplethysmogram (PPG) sensor on the forehead could help minimise this problem and make it easier for other important medical equipment, such as cannulas, to be placed on the limbs. This study compares heart rates measured with a forehead-based PPG sensor against a wrist-based PPG sensor in 19 critically unwell infants in neonatal intensive care collecting 198 h of data. The two heart rates were compared using positive percentage agreement, Spearman's correlation coefficient and Bland-Altman analysis. The forehead PPG sensor showed good agreement with the wrist-based PPG sensor with limits of agreement of 8.44 bpm, bias of -0.22 bpm; positive percentage agreement of 98.87%; and Spearman's correlation coefficient of 0.9816. The analysis demonstrates that the forehead is a reliable alternative location for measuring vital signs using the PPG.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10110846PMC
http://dx.doi.org/10.3389/fphys.2023.1127419DOI Listing

Publication Analysis

Top Keywords

ppg sensor
20
heart rate
16
critically unwell
12
neonatal intensive
8
intensive care
8
unwell infants
8
heart rates
8
wrist-based ppg
8
positive percentage
8
percentage agreement
8

Similar Publications

Study Objectives: This paper validates TipTraQ, a compact home sleep apnea testing (HSAT) system. TipTraQ comprises a fingertip-worn device, a mobile application, and a cloud-based deep learning artificial intelligence (AI) system. The device utilizes PPG (red, infrared, and green channels) and accelerometer sensors to assess sleep apnea by the AI system.

View Article and Find Full Text PDF

Objective: The detection of arterial pulsating signals at the skin periphery with Photoplethysmography (PPG) are easily distorted by motion artifacts. This work explores the alternatives to the aid of PPG reconstruction with movement sensors (accelerometer and/or gyroscope) which to date have demonstrated the best pulsating signal reconstruction.

Approach: A generative adversarial network with fully connected layers (FC-GAN) is proposed for the reconstruction of distorted PPG signals.

View Article and Find Full Text PDF

Objective: The detection of arterial pulsating signals at the skin periphery with Photoplethysmography (PPG) are easily distorted by motion artifacts. This work explores the alternatives to the aid of PPG reconstruction with movement sensors (accelerometer and/or gyroscope) which to date have demonstrated the best pulsating signal reconstruction.

Approach: A generative adversarial network with fully connected layers (FC-GAN) is proposed for the reconstruction of distorted PPG signals.

View Article and Find Full Text PDF

Photoplethysmography is a widely used optical technique to extract physiological information non-invasively. Despite its large use and adoption, multiple factors influence the signal shape and quality, including the instrumentation used. This work analyzes the variability of the DC component of the PPG signal at three source-detector distances (6 mm, 9 mm, and 12 mm) using green, red, and infrared light and four photodiodes per distance.

View Article and Find Full Text PDF

The integration of liveness detection into biometric systems is crucial for countering spoofing attacks and enhancing security. This study investigates the efficacy of photoplethysmography (PPG) signals, which offer distinct advantages over traditional biometric techniques. PPG signals are non-invasive, inherently contain liveness information that is highly resistant to spoofing, and are cost-efficient, making them a superior alternative for biometric authentication.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!