Background: The COVID-19 pandemic necessitated rapid implementation of continuous glucose monitoring (CGM) in the intensive care unit (ICU). Although rarely reported, perceptions from nursing staff who used the systems are critical for successful implementation and future expanded use of CGM in the inpatient setting.

Methods: A 22-item survey focused on CGM use was distributed to ICU nurses at two large academic medical centers in the United States in 2022. Both institutions initiated inpatient CGM in the spring of 2020 using the same CGM+point of care (POC) hybrid protocol. The survey employed a 1- to 5-point Likert scale regarding CGM sensor insertion, accuracy, acceptability, usability, training, and perceptions on workload.

Results: Of the 71 surveys completed, 68 (96%) nurses reported they cared for an ICU patient on CGM and 53% reported they had independently performed CGM sensor insertion. The ICU nurses overwhelmingly reported that CGM was accurate, reduced their workload, provided safer patient care, and was preferred over POC glucose testing alone. Interestingly, nearly half of nurses (49%) reported that they considered trend arrows in dosing decisions although trends were not included in the CGM+POC hybrid protocol. Nurses received training through multiple modalities, with the majority (80%) of nurses reporting that CGM training was sufficient and prepared them for its use.

Conclusion: These results confirm nursing acceptance and preference for CGM use within a hybrid glucose monitoring protocol in the ICU setting. These data lay a blueprint for successful implementation and training strategies for future widespread use.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10210097PMC
http://dx.doi.org/10.1177/19322968231170616DOI Listing

Publication Analysis

Top Keywords

glucose monitoring
12
cgm
10
continuous glucose
8
intensive care
8
care unit
8
successful implementation
8
icu nurses
8
hybrid protocol
8
cgm sensor
8
sensor insertion
8

Similar Publications

Effect of Medium Chain Triglycerides and Whey Protein Isolate Preloads on Glycaemia in Type 2 Diabetes: A randomised crossover study.

Am J Clin Nutr

December 2024

MRC Versus Arthritis Centre for Musculoskeletal Ageing Research, School of Life Sciences, University of Nottingham, Queen's Medical Centre, Nottingham, United Kingdom. Electronic address:

Background: Small nutritional preloads can reduce postprandial glucose excursions in individuals with and without metabolic syndrome or T2D. However, most studies have focused on preloads administered before single meals and have predominantly used protein-based preloads.

Objective: To investigate the effects of sequential consumption of medium chain triglycerides (MCT) and whey protein isolate (WPI) preloads before breakfast lunch and dinner on postprandial, diurnal and 24h glycaemia in individuals with T2D.

View Article and Find Full Text PDF

Highly Efficient Analysis on Biomass Carbohydrate Mixtures by DREAMTIME NMR Spectroscopy.

Anal Chem

December 2024

Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, State Key Laboratory of Physical Chemistry of Solid Surfaces, Xiamen University, Siming South Road 422, Xiamen 361005, China.

Proton (H) NMR spectroscopy presents a powerful tool for biomass mixture studies by revealing the involved chemical compounds with identified ingredients and molecular structures. However, conventional H NMR generally suffers from spectral congestion when measuring biomass mixtures, particularly biomass carbohydrate samples, that contain various physically and chemically similar compounds. In this study, a targeted detection NMR approach, DREAMTIME, is exploited for studying biomass carbohydrate mixtures by spectroscopically targeting the desired compounds in separate 1D NMR spectra.

View Article and Find Full Text PDF

Background: Insomnia is a modifiable risk factor for type 2 diabetes.

Objective: Describe the methodology for the Sleep for Health study, a randomized clinical trial examining the effectiveness of digital cognitive behavioral therapy for insomnia (dCBT-I) in reducing hyperglycemia in 300 people with both insomnia and prediabetes.

Outcomes: Primary outcome is glucose level 2 h after a 75-g glucose load.

View Article and Find Full Text PDF

Sodium-glucose cotransporter 2 inhibitors (SGLT2Is) and angiotensin receptor-neprilysin inhibitor (ARNI) may cause potential renal damage, the combined impact of SGLT2Is and ARNI on acute kidney injury (AKI) remains unclear. This pharmacovigilance study conducted a disproportionality analysis using reports from the FAERS database. The reporting odds ratio (ROR) was used as an estimate for detecting AKI signal.

View Article and Find Full Text PDF

A comprehensive review of non-invasive optical and microwave biosensors for glucose monitoring.

Biosens Bioelectron

December 2024

Programa de Pós-Graduação em Engenharia Elétrica, Universidade Federal de Minas Gerais, Belo Horizonte, MG, 31270-901, Brazil; Departamento de Engenharia Eletrônica, Universidade Federal de Minas Gerais, Belo Horizonte, MG, 31270-901, Brazil. Electronic address:

Frequent glucose monitoring is essential for effective diabetes management. Currently, glucose monitoring is done using invasive methods such as finger-pricking and subcutaneous sensing. However, these methods can cause discomfort, heighten the risk of infection, and some sensing devices need frequent calibration.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!