In recent intelligent-robot-assisted surgery studies, an urgent issue is how to detect the motion of instruments and soft tissue accurately from intra-operative images. Although optical flow technology from computer vision is a powerful solution to the motion-tracking problem, it has difficulty obtaining the pixel-wise optical flow ground truth of real surgery videos for supervised learning. Thus, unsupervised learning methods are critical. However, current unsupervised methods face the challenge of heavy occlusion in the surgical scene. This paper proposes a novel unsupervised learning framework to estimate the motion from surgical images under occlusion. The framework consists of a Motion Decoupling Network to estimate the tissue and the instrument motion with different constraints. Notably, the network integrates a segmentation subnet that estimates the segmentation map of instruments in an unsupervised manner to obtain the occlusion region and improve the dual motion estimation. Additionally, a hybrid self-supervised strategy with occlusion completion is introduced to recover realistic vision clues. Extensive experiments on two surgical datasets show that the proposed method achieves accurate motion estimation for intra-operative scenes and outperforms other unsupervised methods, with a margin of 15% in accuracy. The average estimation error for tissue is less than 2.2 pixels on average for both surgical datasets.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/TMI.2023.3268774 | DOI Listing |
Nat Commun
December 2024
KoBold Metals, Berkeley, CA, USA.
Plate tectonics is a unique feature of Earth, but its proposed time of initiation is still controversial, with published estimates ranging from ca. 4.2 to 0.
View Article and Find Full Text PDFEnviron Technol
December 2024
Department of Mechanical and Aerospace Engineering, Missouri University of Science and Technology, Rolla, MO, USA.
A novel air-to-liquid mass transfer system using wetted rotating membranes was designed to enhance air-to-liquid carbon dioxide (CO) mass transfer efficiency. Traditional methods, such as sparging, are energy-intensive, but the rotating membrane reduces energy demands by optimising membrane wetting via rotational motion. Experimental tests were conducted using a small-scale system with a membrane width of 0.
View Article and Find Full Text PDFJ Am Geriatr Soc
December 2024
NIA-Layton Aging & Alzheimer's Disease Research Center, Oregon Health & Science University, Portland, Oregon, USA.
Background: Life-space mobility can be a behavioral indicator of loneliness. This study examined the association between life-space mobility measured with motion sensors and weekly vs. annually reported loneliness.
View Article and Find Full Text PDFJ Neuroeng Rehabil
December 2024
The School of Information Science and Technology, Dalian Maritime University, Dalian, 116026, China.
Background: Simultaneous and proportional control (SPC) based on surface electromyographic (sEMG) signals has emerged as a research hotspot in the field of human-machine interaction (HMI). However, the existing continuous motion estimation methods mostly have an average Pearson coefficient (CC) of less than 0.85, while high-precision methods suffer from the problem of long inference time (> 200 ms) and can only estimate SPC of less than 15 hand movements, which limits their applications in HMI.
View Article and Find Full Text PDFPract Radiat Oncol
December 2024
Department of Radiation Oncology, Willis Knighton Cancer Center, 2600 Kings Highway, Shreveport, Louisiana, USA 71103 &, Department of Clinical Research, University of Jamestown, Fargo, ND, USA. Electronic address:
Purpose: Motion management presents a significant challenge in thoracic stereotactic ablative radiotherapy (SABR). Currently, a 5.0 mm standard planning target volume (PTV) margin is widely used to ensure adequate dose to the tumor.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!