Particle and gas phase sampling of PCDD/Fs and dl-PCBs by activated carbon fiber and GC/MS analysis.

Environ Sci Pollut Res Int

Italian National Research Council, Institute of Atmospheric Pollution Research, Area Della Ricerca Di Roma 1, 00010, Montelibretti (RM), Italy.

Published: May 2023

Polychlorodibenzo-p-dioxins (PCDDs), polychlorodibenzofurans (PCDFs), and polychlorobiphenyls (PCBs) are semi-volatile compounds and can be partitioned in the atmosphere between the gas and particulate phase, due to their physicochemical properties. For this reason, the reference standard methods for air sampling include a quartz fiber filter (QFF) for the particulate and a polyurethane foam (PUF) cartridge for the vapor phase, and it is the classical and most popular sampling method in the air. Despite the presence of the two adsorbing media, this method cannot be used for the study of the gas-particulate distribution, but only for a total quantification. This study presents the results and the performance aim to validate an activated carbon fiber (ACF) filter for the sampling of PCDD/Fs and dioxin-like PCBs (dl-PCBs) using laboratory and field tests. The specificity, precision, and accuracy of the ACF in relation to the QFF + PUF were evaluated through the isotopic dilution technique, the recovery rates, and the standard deviations. Then the ACF performance was assessed on real samples, in a naturally contaminated area, through parallel sampling with the reference method (QFF + PUF). The QA/QC was defined according to the standard methods ISO 16000-13 and -14 and EPA TO4A and 9A. Data confirmed that ACF meets the requirements for the quantification of native POPs compounds in atmospheric and indoor samples. In addition, ACF provided accuracy and precision comparable to those offered by standard reference methods using QFF + PUF, but with significant savings in terms of time and costs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10182933PMC
http://dx.doi.org/10.1007/s11356-023-27052-8DOI Listing

Publication Analysis

Top Keywords

sampling pcdd/fs
8
activated carbon
8
carbon fiber
8
standard methods
8
sampling
5
acf
5
particle gas
4
gas phase
4
phase sampling
4
pcdd/fs dl-pcbs
4

Similar Publications

This study proposed a novel closed-wet accelerated carbonation method based on ultrasonic chemistry for treating municipal solid waste incineration fly ash (MSWI FA), assessing various reaction parameters (time, temperature, CO pressure, ultrasonic power, and alkaline additives) on the detoxification and synergistic carbon fixation. The mechanisms of carbon sequestration, heavy metal migration-stabilization, and PCDD/Fs migration-degradation were elucidated. Key findings include the reaction kinetic of MSWI FA ultrasonic carbonation aligning with the surface coverage model (R > 0.

View Article and Find Full Text PDF

Polychlorinated dibenzo-dioxin/furan and polychlorinated biphenyl concentrations in the human milk of individuals living near municipal waste incinerators in the UK: Findings from the Breast milk, Environment, Early-life, and development (BEED) human biomonitoring study.

Environ Res

December 2024

Department of Epidemiology and Biostatistics, Imperial College London, London, UK; NIHR Health Protection Research Unit on Chemical Radiation Threats and Hazards, Imperial College London, London, UK; MRC Centre for Environment and Health, Imperial College London, London, UK; National Institute for Health Research (NIHR) Health Protection Research Unit in Environmental Exposures and Health, Imperial College London, London, UK; Mohn Centre for Children's Health and Wellbeing, School of Public Health, Imperial College London, London, UK. Electronic address:

The objective of this study is to report recent PCDD/F and PCB human milk concentrations in the United Kingdom (UK) and relate these to two proxies for exposure to municipal waste incinerator (MWI) emissions. As part of the Breast milk, Environment, Early-life, and Development (BEED) study, primiparous individuals were recruited from within 20 km of English MWIs between 2013 and 2015 and asked to provide human milk samples. The samples were analysed for quantitative concentrations of 17 PCDD/F and 12 PCB congeners.

View Article and Find Full Text PDF

Direct measurements and comparisons of dry deposition fluxes and velocities of PCDD/Fs with two samplers.

Environ Pollut

January 2025

Department of Environmental Engineering, Faculty of Engineering, Bursa Uludag University, 16059, Nilüfer, Bursa, Turkey. Electronic address:

Polychlorinated dibenzo-p-dioxins/furans (PCDD/Fs) are toxic and persistent pollutants that raise concerns due to their accumulative characteristics in the environments and biota. Atmospheric PCDD/Fs can enter various recipient environments and impact the entire ecosystem, thereby arousing more attention. Dry deposition is deemed the dominant migration pathway of atmospheric PCDD/Fs owing to their predominant distributions in the particulate phase.

View Article and Find Full Text PDF

A novel approach to the extraction and analysis of dioxins and furans sampled onto Amberlite XAD-2 sorbent.

Anal Methods

December 2024

Department of Chemistry, Faculty of Natural and Agricultural Sciences, University of Pretoria, Pretoria, South Africa.

Article Synopsis
  • Strong emission control plans have successfully reduced pollutants, yet PCDDs and PCDFs are still emitted from sources like waste incinerators, necessitating effective monitoring due to their high toxicity.
  • Current analysis of these compounds in Africa is costly and limited, often done overseas, leading to fewer measurements and less data.
  • A new, cost-effective laboratory method for analyzing PCDD/Fs was developed, significantly simplifying extraction and clean-up processes, achieving comparable recovery rates to established methods while being faster and more efficient.
View Article and Find Full Text PDF

The polychlorinated dibenzo-p-dioxins/furans (PCDD/Fs) and dioxin-like polychlorinated biphenyls (dl-PCBs) are worldwide contaminants, and they tend to accumulate in wide variety of matrices. Therefore, due to the highest accumulation rate and recalcitrancy, their precise quantification makes significant concern about their toxicological effects on both humans and organisms. The objective of the study is that using hydrogen carrier gas instead of helium in gas chromatography with triple quadrupole (GC-MS/MS) systems could contribute to improvements on the analysis of dl-PCBs and PCDD/Fs in environmental matrices.

View Article and Find Full Text PDF