A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Validation of a single-use and reusable home sleep apnea test based on peripheral arterial tonometry compared to laboratory polysomnography for the diagnosis of obstructive sleep apnea. | LitMetric

Study Objectives: The objective of this study was to independently validate a disposable and a reusable home sleep apnea test (HSAT) recording on peripheral arterial tonometry, compared to laboratory polysomnography (PSG), for the diagnosis of obstructive sleep apnea (OSA).

Methods: 115 participants undergoing PSG for suspected OSA were recruited and fitted with the two study devices (NightOwl, Ectosense, Belgium). After exclusions were applied and device failures were removed, data from 100 participants were analyzed. HSAT-derived apnea-hypopnea index (AHI), OSA severity category, total sleep time, and oxygen desaturation index 3% were compared to PSG.

Results: Both study devices demonstrated satisfactory levels of agreement with minimal mean bias for determination of AHI and oxygen desaturation index 3% (disposable: AHI mean bias 2.04 events/h [95% limits of agreement -20.9 to 25.0], oxygen desaturation index 3% mean bias -0.21/h [-18.1 to 17.7]; reusable: AHI mean bias 2.91 events/h [-16.9 to 22.7], oxygen desaturation index 3% mean bias 0.77/h [-15.7 to 17.3]). Level of agreement diminished at higher AHI levels although misclassification for severe OSA occurred infrequently. Total sleep time level of agreement for the reusable HSAT was also satisfactory with minimal mean bias (4.18 minutes, -125.1 to 112.4), but the disposable HSAT was impacted by studies with high signal rejection (23.7 minutes, -132.7 to 180.1). Categorization of OSA severity demonstrated moderate agreement with laboratory PSG, with a kappa of 0.52 and 0.57 for the disposable and reusable HSATs respectively.

Conclusions: The two HSAT devices were comparable and performed well compared to laboratory PSG for the diagnosis of OSA.

Clinical Trial Registration: Registry: Australian New Zealand Clinical Trials Registry; Identifier: ANZCTR12621000444886.

Citation: Lyne CJ, Hamilton GS, Turton ARE, et al. Validation of a single-use and reusable home sleep apnea test based on peripheral arterial tonometry compared to laboratory polysomnography for the diagnosis of obstructive sleep apnea. . 2023;19(8):1429-1435.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10394370PMC
http://dx.doi.org/10.5664/jcsm.10568DOI Listing

Publication Analysis

Top Keywords

sleep apnea
24
compared laboratory
16
oxygen desaturation
16
reusable sleep
12
apnea test
12
peripheral arterial
12
arterial tonometry
12
tonometry compared
12
laboratory polysomnography
12
diagnosis obstructive
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!