Background: To analyze the relationship between the rotational and residual setup errors and the dose deviation on nasopharyngeal carcinoma (NPC) treated by helical tomotherapy (HT).
Methods: From 25 July 2017 to 20 August 2019, 16 treated NPC patients were enrolled in the study. These patients were scanned with full target range megavoltage computed tomography (MVCT) every other day. Adaptive radiotherapy function application software MIM7.1.3 were used to accumulate the actual dose. The dose deviation with the initial plan dose of the patients' target and organs at risk (OAR) were compared, and the correlation between the dose change and the setup errors (rotational setup errors and neck residual setup error) was analyzed.
Results: Translational setup errors increased farther away from the head. Statistically significant difference among 3 groups was achieved in the directions of left-right ( < .001) and anteroposterior ( < .001) by analysis of variance test. Compared with the initial plan dose, the actual accumulated dose of the target area decreased with the actual exposure dose of the OAR increased. However, most of the dosimetric parameters differed by less than 5%. No correlation was found between dose deviation values and the translational setup errors of target. However, sagittal rotational setup errors (pitch) had a positive relationship ( < .05) with the avearge dose of PTVnd (L) ( = 0.885), PTVnd(R) ( = 0.547) PTV1( = 0.633) and PTV2( = 0.584). Transverse rotational setup errors (roll) had a positive relationship ( < .05) with the avearge dose of PTVnd(R) ( = 0.593), PTV1( = 0.505) and PTV2( = 0.662).
Conclusions: Dose deviation between the actual accumulated and initial plan is not negligible, but most indicators difference is less than 5%, NPC patients treated by HT with MVCT correction setup errors every other day did not need adaptive radiotherapy model unless got rapid tumor shrinkage or weight loss. Moreover, to minimize the dose deviation, more attention should be paid to the reduction of pitch, roll, and residual error of cervical vertebrae during body positioning.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10126667 | PMC |
http://dx.doi.org/10.1177/15330338231169601 | DOI Listing |
Indian J Psychiatry
November 2024
Department of Psychiatry, All India Institute of Medical Sciences, New Delhi, India.
Background: Functional near-infrared spectroscopy (fNIRS) is being increasingly utilized to visualize the brain areas involved in cognitive activity to understand the human brain better. Its portability and easy setup give it an advantage over other functional brain imaging tools. The current study utilizes fNIRS while performing a Stroop test, which is commonly used to assess the impairment of information selection in depression.
View Article and Find Full Text PDFMed Phys
January 2025
Department of Radiation Oncology, Inha University Hospital, Incheon, Republic of Korea.
Background: High-dose-rate (HDR) brachytherapy using Iridium-192 as a radiation source is widely employed in cancer treatment to deliver concentrated radiation doses while minimizing normal tissue exposure. In this treatment, the precision with which the sealed radioisotope source is delivered significantly impacts clinical outcomes.
Purpose: This study aims to evaluate the feasibility of a new four-dimensional (4D) in vivo source tracking and treatment verification system for HDR brachytherapy using a patient-specific approach.
ISA Trans
December 2024
Group of Power Systems, Catalonia Institute for Energy Research (IREC), Jardins de les Dones de Negre, 1, 08930, Sant Adrià del Besòs, Spain. Electronic address:
This paper presents the design and implementation of a deep-learning-based observer for accurately estimating the State of Charge (SoC) of a vanadium flow battery. The novelty of the proposal lies in its direct use of terminal voltage and the application of a machine learning algorithm to model the battery's overpotentials, leading to greater accuracy and reduced complexity compared to classical models. The overpotentials model consists of a neural network trained using data generated by a classical observer that estimates species concentration using a physical electrochemical model and the open-circuit voltage measurement.
View Article and Find Full Text PDFJ Vis
January 2025
Magic Leap Switzerland GmbH, Zürich, Switzerland.
When rendering the visual scene for near-eye head-mounted displays, accurate knowledge of the geometry of the displays, scene objects, and eyes is required for the correct generation of the binocular images. Despite possible design and calibration efforts, these quantities are subject to positional and measurement errors, resulting in some misalignment of the images projected to each eye. Previous research investigated the effects in virtual reality (VR) setups that triggered such symptoms as eye strain and nausea.
View Article and Find Full Text PDFPhys Eng Sci Med
January 2025
School of Clinical Sciences, Queensland University of Technology, Brisbane, QLD, Australia.
Set-up errors are a problem for pre-clinical irradiators that lack imaging capabilities. The aim of this study was to investigate the impact of the potential set-up errors on the dose distribution for a mouse with a xenographic tumour irradiated with a standard Cs-137 cell irradiator equipped with an in-house lead collimator with 10 mm diameter apertures. The EGSnrc Monte-Carlo (MC) code was used to simulate the potential errors caused by displacements of the mouse in the irradiation setup.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!