Purpose Of Review: Optical coherence tomography angiography (OCTA) is a novel, noninvasive imaging technique, which provides depth resolved visualization of microvasculature of the retina and choroid. Although OCTA has been widely used for the evaluation of a number of retinal diseases, its use in the field of neuro-ophthalmology has been less studied. In this review, we provide an update on the utility of OCTA in neuro-ophthalmic conditions.
Recent Findings: Peripapillary and macular microvasculature analyses have indicated that OCTA can be a promising tool for early detection of a number of neuro-ophthalmic diseases, differential diagnosis, and monitoring of disease progression. Recent studies have demonstrated that structural and functional impairment can develop at early stages in some conditions such as in multiple sclerosis and Alzheimer's disease even in the absence of overt clinical symptoms. Furthermore, this dye-less technique can be a valuable adjunct tool in the detection of complications commonly seen in some congenital entities such optic disc drusen.
Summary: Since its introduction, OCTA has emerged as an important imaging approach shedding light on unrevealed pathophysiological mechanisms of several ocular diseases. The use of OCTA as a biomarker in the field of neuro-ophthalmology has recently gained considerable attention with studies supporting its role in clinical setting while larger studies are warranted for correlating these findings with traditional diagnostic procedures and clinical features and outcomes.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/ICU.0000000000000955 | DOI Listing |
Ophthalmologie
January 2025
Klinik für Augenheilkunde, Universitätsklinikum Ulm, Prittwitzstr. 43, 89075, Ulm, Deutschland.
Comprehensive multimodal imaging is essential for the precise clinical diagnostics of neovascular age-related macular degeneration (nAMD). Noninvasive optical coherence tomography (OCT) is of prime importance regarding the baseline examination, follow-up and monitoring during treatment. The OCT imaging in nAMD eyes enables a high-resolution assessment of the retinal micromorphology, which can be considerably disturbed in different layers.
View Article and Find Full Text PDFSci Rep
January 2025
Centre for Informatics and Systems of the University of Coimbra, Department of Informatics Engineering, University of Coimbra, Coimbra, Portugal.
Assessing cognitive load using pupillography frequency features presents a persistent challenge due to the lack of consensus on optimal frequency limits. This study aims to address this challenge by exploring pupillography frequency bands and seeking clarity in defining the most effective ranges for cognitive load assessment. From a controlled experiment involving 21 programmers performing software bug inspection, our study pinpoints the optimal low-frequency (0.
View Article and Find Full Text PDFKlin Monbl Augenheilkd
January 2025
Ophthalmology, Talacker Eye Center Zurich (TAZZ), Switzerland.
Background: Nineteen-year follow-up after initial examination on patients with Axenfeld-Rieger anomaly or syndrome (ARAS) and coexisting Fuchs' endothelial dystrophy (FED). All individuals had previously been tested positive for the PITX2 (g.20 913 G>T) mutation.
View Article and Find Full Text PDFHear Res
January 2025
Columbia University Irving Medical Center, Department of Otolaryngology, Head and Neck Surgery, 180 Fort Washington Ave, New York, 10032, NY, USA; Columbia University, Department of Biomedical Engineering, 1210 Amsterdam Ave, New York, 10027, NY, USA.
Sound-evoked displacement responses at the outer hair cell-Deiters' cell junction (OHC-DC) are of significant interest in cochlear mechanics, as OHCs are believed to be in part responsible for active tuning enhancement and amplification. Motion in the cochlea is three-dimensional, and the architecture of the organ of Corti complex (OCC) suggests the presence and mechanical importance of all three components of motion. Optical coherence tomography (OCT) displacement measurements of OHC-DC motion from different experimental preparations often show disparate results, potentially due to OCT measuring only the motion component along the beam axis.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!