A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Bleb morphology of glaucoma drainage devices on magnetic resonance imaging. | LitMetric

Purpose: To evaluate bleb morphology features of different glaucoma drainage devices (GDD) using magnetic resonance imaging (MRI).

Materials And Methods: Prospective cohort study of GDD and bleb morphology in consecutive glaucoma patients implanted with Ahmed Glaucoma Valve (AGV), Paul Glaucoma Implant (PGI), Baerveldt Glaucoma Implant (BGI) and Ahmed ClearPath (ACP) devices. Thirty-six eyes from 30 consecutive patients underwent standardized GDD implantation followed by MRI at least 1 month after surgery. Main outcomes included bleb volume and endplate position relative to the optic nerve. Secondary outcomes included intraocular pressure (IOP), medication and surgical complications during a 12-month follow-up.

Results: Seven eyes were implanted with the AGV (19%), 5 with BGI (14%), 16 with PGI (44%) and 8 with ACP (22%). MRI scans were obtained 85 ± 66 days after surgery. Mean total bleb volume was 563 ± 390 mm . This bleb volume was inversely correlated with early post-operative IOP (day 7; r  = -0.3326, p = 0.0475) but positively correlated with IOP at 12 months (r  = 0.3592, p = 0.0341). No significant difference in total bleb volume was found between GDD types (p = 0.1223). A double-layered bleb was observed in 34 eyes (94%). The inferior bleb volume was significantly larger in PGI devices versus other GDD types (380 ± 205 vs. 193 ± 161 mm ; p = 0.0043). Distance from the endplate to the optic nerve was 9.5 ± 4.0 mm, similar across GDDs (p = 0.2519).

Conclusions: Double-layered blebs are a common finding with GDDs. Bleb volume showed different correlations with IOP at distinct timepoints and the PGI device formed larger blebs. A standardized GDD implantation technique ensures a safe distance from the GDD endplate to the optic nerve.

Download full-text PDF

Source
http://dx.doi.org/10.1111/aos.15668DOI Listing

Publication Analysis

Top Keywords

bleb volume
24
bleb morphology
12
optic nerve
12
bleb
10
glaucoma drainage
8
drainage devices
8
magnetic resonance
8
resonance imaging
8
glaucoma implant
8
standardized gdd
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!