This study primarily aimed to report the outcome of the arthroscopic cancellous bone grafting technique for treating scaphoid nonunion. The secondary aim was to compare the bone union rate and time, and the ability to correct the angulation of the scaphoid, between arthroscopically treated patients ( = 27), and patients treated with open cancellous bone grafting ( = 27). Nine surgeons (two in the arthroscopic and seven in the open group) with Level III experience operated on the patients. The pain score, grip strength and Quick Disability of the Arm, Shoulder and Hand score improved significantly after the arthroscopic treatment ( = 0.0001). Arthroscopic cancellous bone grafting achieved union in 25 out of 27 patients. A retrospective comparison with open cancellous bone grafting showed four nonunions. Arthroscopically treated patients healed 5.4 weeks faster compared with the open group (= 0.033). Patients treated with open grafting had a higher risk of failure (odds ratio = 2.17), although this was not found significant (= 0.39). The open method corrected the angulation deformity better (dorsal cortical angle correction of 4°) than the arthroscopic method (dorsal cortical angle correction of 1°), but this was not statistically significant neither within the groups (= 0.55, 0.87) nor postoperatively between the groups (= 0.98). The height-to-length ratio was not different before and after the surgery for the arthroscopic group (= 0.44) and the open group (= 0.27), or postoperatively between the groups (= 0.44). III.

Download full-text PDF

Source
http://dx.doi.org/10.1177/17531934231166343DOI Listing

Publication Analysis

Top Keywords

cancellous bone
24
bone grafting
24
arthroscopic cancellous
12
open cancellous
12
open group
12
scaphoid nonunion
8
open
8
comparison open
8
arthroscopically treated
8
treated patients
8

Similar Publications

A data-driven framework for developing a unified density-modulus relationship for the human lumbar vertebral body.

J Mech Behav Biomed Mater

January 2025

Department of Mechanical Engineering, Boston University, Boston, MA 02215, USA; Center for Multiscale and Translational Mechanobiology, Boston University, Boston, MA 02215, USA; Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA.

Despite the broad agreement that bone stiffness is heavily dependent on the underlying bone density, there is no consensus on a unified relationship that applies to both cancellous and cortical compartments. Bone from the two compartments is generally assessed separately, and few mechanical test data are available for samples from the transitional regions between them. In this study, we present a data-driven framework integrating experimental testing and numerical modeling of the human lumbar vertebra through an energy balance criterion, to develop a unified density-modulus relationship across the entire vertebral body, without the necessity of differentiation between trabecular and cortical regions.

View Article and Find Full Text PDF

OI, or bone brittle disease, is characterized by increased mineralization of bone matrix independently of clinical severity. So, a beneficial effect of antiresorptive treatments such as bisphosphonates (BP) is questionable. We aim to compare the bone matrix characteristics before and after BP pamidronate (PAM).

View Article and Find Full Text PDF

Background: Surgical management methods for Hepple IV-V osteochondral lesions of the talus (OLT) are diverse. This study aimed to compare the clinical efficacy of arthroscopic autologous cancellous bone grafting and medial malleolar osteotomy combined with autologous periosteal iliac bone grafting in the treatment of medial Hepple IV-V OLT.

Methods: A retrospective analysis of clinical data from patients who underwent surgical treatment for Hepple IV-V OLT (2020-2023) was conducted.

View Article and Find Full Text PDF

Background: Implant fixation is often the cornerstone of musculoskeletal surgical procedures performed to provide bony fixation and/or fusion. The aim of this study was to evaluate how different design features and manufacturing methods influence implant osseointegration and mechanical properties associated with fixation in a standardized model in cancellous bone of adult sheep.

Methods: We evaluated the performance of three titanium alloy implants: (A) iFuse-TORQ implant; (B) Fenestrated Sacroiliac Device; and (C) Standard Cancellous Bone Screw in the cancellous bone of the distal femur and proximal tibia in 8 sheep.

View Article and Find Full Text PDF

Background: While there have been significant advancements in recent years, complications following fixation for femoral neck fractures remain a concern. This retrospective cohort study aimed to investigate the influence of polytrauma and additional fractures on the occurrence of complications in patients who underwent surgical fixation for femoral neck fractures. The study focused on analyzing patient demographics, comorbidities, fracture classifications, fixation methods, and the likelihood of experiencing post-operative complications, with a specific emphasis on the impact of polytrauma and additional fractures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!