There are no currently available low-cost, noninvasive methods for discerning the depth of squamous cell carcinoma (SCC) invasion or distinguishing SCC from its benign mimics, such as inflamed seborrheic keratosis (SK). We studied 35 subjects with subsequently confirmed SCC or SK. Subjects underwent electrical impedance dermography measurements at six frequencies to assess the electrical properties of the lesion. Averaged greatest intrasession reproducibility values were 0.630 for invasive SCC at 128 kHz, 0.444 for SCC in situ at 16 kHz, and 0.460 for SK at 128 kHz. Electrical impedance dermography modeling revealed significant differences between SCC and inflamed SK in normal skin ( < 0.001) and also between invasive SCC and SCC in situ ( < 0.001), invasive SCC and inflamed SK ( < 0.001), and SCC in situ and inflamed SK ( < 0.001). A diagnostic algorithm classified SCC in situ from inflamed SK with an accuracy of 0.958, a sensitivity of 94.6%, and a specificity of 96.9%; it also classified SCC in situ from normal skin with an accuracy of 0.796, a sensitivity of 90.2%, and a specificity of 51.2%. This study provides preliminary data and a methodology that can be used in future studies to further advance the value of electrical impedance dermography and inform biopsy decision making in patients with lesions suspicious of SCC.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10090659PMC
http://dx.doi.org/10.1016/j.xjidi.2023.100194DOI Listing

Publication Analysis

Top Keywords

electrical impedance
12
impedance dermography
12
squamous cell
8
cell carcinoma
8
inflamed seborrheic
8
scc
8
invasive scc
8
128 khz
8
scc situ
8
electrical
4

Similar Publications

Detection of Extracochlear Electrodes Using Electrical Field Imaging (EFI).

Otol Neurotol

February 2025

Department of Otolaryngology-Head and Neck Surgery, Mayo Clinic, Rochester, Minnesota.

Objective: To analyze the use of electrical field imaging (EFI) in the detection of extracochlear electrodes in cochlear implants (CI).

Study Design: Retrospective cohort study.

Setting: Tertiary academic medical center.

View Article and Find Full Text PDF

There are limited studies on the phase angle (PhA) and sarcopenic obesity (SO) in the Chinese population. This study aimed to establish 50 kHz-PhA reference data for SO population, and to evaluate the correlation between 50 kHz-PhA and SO. A total of 10,312 participants including 5415 men and 4897 women were enrolled in this study, and their resistance and reactance at 50 kHz, and body composition parameters were measured a segmental multifrequency bioelectrical impedance analysis device (InBody 720).

View Article and Find Full Text PDF

The overall goal of this work was to assess the ability of Natural Killer cells to kill cultures of patient-derived glioblastoma cells. Herein we report impressive levels of NK-92 mediated killing of various patient-derived glioblastoma cultures observed at ET (effector: target) ratios of 5:1 and 1:1. This enabled direct comparison of the degree of glioblastoma cell loss across a broader range of glioblastoma cultures.

View Article and Find Full Text PDF

Heterostructures comprise two or more different semiconducting materials stacked either as co-assemblies or self-sorted based on their dynamics of aggregates. However, self-sorting in heterostructures is rather significant in improving the short exciton diffusion length and charge separation. Despite small organic molecules being known for their self-sorting nature, macrocyclic are hitherto unknown owing to unrestrained assemblies from extended π-conjugated systems.

View Article and Find Full Text PDF

Wireless power-up and readout from a label-free biosensor.

Biomed Microdevices

January 2025

Department of Electrical and Computer Engineering, Rutgers University, Piscataway, NJ, 08854, USA.

Wearable and implantable biosensors have rapidly entered the fields of health and biomedicine to diagnose diseases and physiological monitoring. The use of wired medical devices causes surgical complications, which can occur when wires break, become infected, generate electrical noise, and are incompatible with implantable applications. In contrast, wireless power transfer is ideal for biosensing applications since it does not necessitate direct connections between measurement tools and sensing systems, enabling remote use of the biosensors.

View Article and Find Full Text PDF