A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determination and disposition of meta-iodobenzylguanidine in plasma and heart of transporter-deficient mice by UPLC-MS/MS. | LitMetric

Determination and disposition of meta-iodobenzylguanidine in plasma and heart of transporter-deficient mice by UPLC-MS/MS.

J Chromatogr B Analyt Technol Biomed Life Sci

Division of Pharmaceutics and Pharmacology, College of Pharmacy, The Ohio State University, Columbus, OH, USA. Electronic address:

Published: May 2023

A simple LC-MS/MS method for the quantitative determination of the norepinephrine analogue meta-iodobenzyl-guanidine (mIBG) was developed and validated for mouse plasma and tissues, including salivary gland and heart. The assay procedure involved a one-step solvent extraction of mIBG and the internal standard N-(4-fluorobenzyl)-guandine from plasma or tissue homogenates with acetonitrile. An Accucore aQ column was used to separate analytes using a gradient elution with a total run time of 3.5 min. Validation studies with quality control samples processed on consecutive days revealed values for intra-day and inter-day precision of < 11.3%, with values for accuracy ranging 96.8-111%. Linear responses were observed over the entire calibration curves range (up to 100 ng/mL), and the lower limit of quantification was 0.1 ng/mL, using sample volumes of 5 µL. The developed method was successfully applied to evaluate the plasma pharmacokinetics and tissue distribution of mIBG in wild-type mice and animals lacking the organic cation transporters OCT1, OCT2, OCT3, and/or MATE1 to further understand mechanisms contributing to drug distribution and elimination and causes of inter-individual pharmacokinetic variability.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2023.123699DOI Listing

Publication Analysis

Top Keywords

determination disposition
4
disposition meta-iodobenzylguanidine
4
meta-iodobenzylguanidine plasma
4
plasma heart
4
heart transporter-deficient
4
transporter-deficient mice
4
mice uplc-ms/ms
4
uplc-ms/ms simple
4
simple lc-ms/ms
4
lc-ms/ms method
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!