Early and high-throughput individual dose estimates are essential following large-scale radiation exposure events. In the context of the Running the European Network for Biodosimetry and Physical Dosimetry (RENEB) 2021 exercise, gene expression assays were conducted and their corresponding performance for dose-assessment is presented in this publication. Three blinded, coded whole blood samples from healthy donors were exposed to 0, 1.2 and 3.5 Gy X-ray doses (240 kVp, 1 Gy/min) using the X-ray source Yxlon. These exposures correspond to clinically relevant groups of unexposed, low dose (no severe acute health effects expected) and high dose exposed individuals (requiring early intensive medical health care). Samples were sent to eight teams for dose estimation and identification of clinically relevant groups. For quantitative reverse transcription polymerase chain reaction (qRT-PCR) and microarray analyses, samples were lysed, stored at 20°C and shipped on wet ice. RNA isolations and assays were run in each laboratory according to locally established protocols. The time-to-result for both rough early and more precise later reports has been documented where possible. Accuracy of dose estimates was calculated as the difference between estimated and reference doses for all doses (summed absolute difference, SAD) and by determining the number of correctly reported dose estimates that were defined as ±0.5 Gy for reference doses <2.5 Gy and ±1.0 Gy for reference doses >3 Gy, as recommended for triage dosimetry. We also examined the allocation of dose estimates to clinically/diagnostically relevant exposure groups. Altogether, 105 dose estimates were reported by the eight teams, and the earliest report times on dose categories and estimates were 5 h and 9 h, respectively. The coefficient of variation for 85% of all 436 qRT-PCR measurements did not exceed 10%. One team reported dose estimates that systematically deviated several-fold from reported dose estimates, and these outliers were excluded from further analysis. Teams employing a combination of several genes generated about two-times lower median SADs (0.8 Gy) compared to dose estimates based on single genes only (1.7 Gy). When considering the uncertainty intervals for triage dosimetry, dose estimates of all teams together were correctly reported in 100% of the 0 Gy, 50% of the 1.2 Gy and 50% of the 3.5 Gy exposed samples. The order of dose estimates (from lowest to highest) corresponding to three dose categories (unexposed, low dose and highest exposure) were correctly reported by all teams and all chosen genes or gene combinations. Furthermore, if teams reported no exposure or an exposure >3.5 Gy, it was always correctly allocated to the unexposed and the highly exposed group, while low exposed (1.2 Gy) samples sometimes could not be discriminated from highly (3.5 Gy) exposed samples. All teams used FDXR and 78.1% of correct dose estimates used FDXR as one of the predictors. Still, the accuracy of reported dose estimates based on FDXR differed considerably among teams with one team's SAD (0.5 Gy) being comparable to the dose accuracy employing a combination of genes. Using the workflow of this reference team, we performed additional experiments after the exercise on residual RNA and cDNA sent by six teams to the reference team. All samples were processed similarly with the intention to improve the accuracy of dose estimates when employing the same workflow. Re-evaluated dose estimates improved for half of the samples and worsened for the others. In conclusion, this inter-laboratory comparison exercise enabled (1) identification of technical problems and corrections in preparations for future events, (2) confirmed the early and high-throughput capabilities of gene expression, (3) emphasized different biodosimetry approaches using either only FDXR or a gene combination, (4) indicated some improvements in dose estimation with FDXR when employing a similar methodology, which requires further research for the final conclusion and (5) underlined the applicability of gene expression for identification of unexposed and highly exposed samples, supporting medical management in radiological or nuclear scenarios.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11106736PMC
http://dx.doi.org/10.1667/RADE-22-00206.1DOI Listing

Publication Analysis

Top Keywords

dose estimates
56
dose
22
gene expression
16
reported dose
16
exposed samples
16
estimates
15
correctly reported
12
highly exposed
12
samples
9
teams
9

Similar Publications

Blood coagulation monitoring of patients with mechanical heart valve visiting Imam.

J Cardiothorac Surg

January 2025

Cardiovascular Research Center, Health Policy and Promotion Institute, Imam-Ali Hospital, Kermanshah University of Medical Sciences, Kermanshah, Iran.

Background: The lacking proper regulation of International Normalized Ratio (INR) as the main problem in patients with mechanical valve replacement surgery poses the risk of thrombosis and embolism on the one hand and the risk of bleeding on the other. For this reason, the correct monitoring of INR via the Time in Therapeutic Range (TTR) is needed. The present study aimed to explore the blood coagulation monitoring of patients with mechanical heart valve in Imam Ali Hospital of Kermanshah in 2021.

View Article and Find Full Text PDF

Background: Serum vitamin D deficiency is intricately linked to metabolic disorders, however, evidence on its association with continuous metabolic risk in children and adolescents remains insufficient. This study aims to elucidate the relationship between serum vitamin D levels and continuous metabolic risk.

Methods: The cross-sectional analysis involved 4490 participants aged 6 ~ 18, and the longitudinal investigation included 1398 individuals aged 6 ~ 12 years.

View Article and Find Full Text PDF

Are psychological attitudes towards vaccination an expression of personality? A cross-sectional study on COVID-19 vaccination in France.

BMC Public Health

January 2025

Emerging Diseases Epidemiology Unit, Institut Pasteur, 25-28 Rue du Docteur Roux, Bâtiment Laveran, Paris, 75015, France.

Background: The capacity of the 7C model's psychological antecedents, which include confidence in vaccines, complacency, convenience, calculation, collective responsibility, confidence in the wider system, and social conformism, to explain variance in COVID-19 vaccine intentions and behaviours has been documented. However, it remains unclear whether the attitudes represented by the 7C psychological antecedents are specific to vaccination or if they are, in fact, an expression of underlying personality traits.

Methods: From February to June 2022, French adults completed self-administered questionnaires assessing COVID-19 vaccination history, the 7C antecedents, and personality traits ("ComCor" and "Cognitiv" studies).

View Article and Find Full Text PDF

Background: Gastrin releasing peptide receptor (GRPR)-directed radiopharmaceuticals for targeted radionuclide therapy may be a very promising addition in prostate and breast cancer patient management. Aiming to provide a GRPR-targeting theranostic pair, we have utilized the Tc-99m/Re-188 radiometal pair, in combination with two bombesin based antagonists, maSSS-PEG2-RM26 and maSES-PEG2-RM26. The two main aims of the current study were (i) to elucidate the influence of the radiometal-exchange on the biodistribution profile of the two peptides and (ii) to evaluate the feasibility of using the [Tc]Tc labeled counterparts for the dosimetry estimation for the [Re]Re-labeled conjugates.

View Article and Find Full Text PDF

Background: Vaccination against HPV is an effective strategy for the prevention of HPV infection and cervical cancer. Nevertheless, the HPV vaccine uptake rate is low among ethnic minorities in Hong Kong. This study sought to assess the feasibility and acceptability of motivational interviewing among South Asian mother-daughter dyads and to preliminarily examine its effects on knowledge of HPV infection and vaccination, health beliefs, intention to have the daughters vaccinated, and initiation and completion of HPV vaccine series.

View Article and Find Full Text PDF