A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Highly Stretchable PPy/PDMS Strain Sensors Fabricated with Multi-Step Oxygen Plasma Treatment. | LitMetric

Highly Stretchable PPy/PDMS Strain Sensors Fabricated with Multi-Step Oxygen Plasma Treatment.

Polymers (Basel)

Division of Electronics and Electrical Engineering, Dongguk University, Seoul 100-175, Republic of Korea.

Published: March 2023

We present highly stretchable polypyrrole (PPy)/polydimethylsiloxane strain sensors of highly improved sensitivity and durability fabricated by a chemical oxidative polymerization with oxygen plasma treatment (O PT). In this study, O PT was performed for 30, 60, and 90 s at each growth stage of the PPy film in three steps to investigate the effects on the sensor performance as well as the microstructural properties of the PPy films. Bonding characteristics with underlying layers and resistance to microcrack generation of the multi-layer PPy films under our given strained state were significantly enhanced by the O PT. The best sensor performance in terms of sensitivity and stability were achieved by PT for 30 s with a maximum gauge factor of ~438 at a uniaxial strain of 50%, excellent durability over 500 stretching/release cycles, and a fast response time of ~50 ms.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10096996PMC
http://dx.doi.org/10.3390/polym15071714DOI Listing

Publication Analysis

Top Keywords

highly stretchable
8
strain sensors
8
oxygen plasma
8
plasma treatment
8
sensor performance
8
ppy films
8
stretchable ppy/pdms
4
ppy/pdms strain
4
sensors fabricated
4
fabricated multi-step
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!