This work investigates the optical properties of Yb ions doped GeO-PbO glasses containing Ag nanoclusters (NCs), produced by the melt-quenching technique. The lack in the literature regarding the energy transfer (ET) between these species in these glasses motivated the present work. Tunable visible emission occurs from blue to orange depending on the Yb concentration which affects the size of the Ag NCs, as observed by transmission electron microscopy. The ET mechanism from Ag NCs to Yb ions (F → F) was attributed to the S→T decay (spin-forbidden electronic transition between singlet-triplet states) and was corroborated by fast and slow lifetime decrease (at 550 nm) of Ag NCs and photoluminescence (PL) growth at 980 nm, for excitations at 355 and 405 nm. The sample with the highest Yb concentration exhibits the highest PL growth under 355 nm excitation, whereas at 410 nm it is the sample with the lowest concentration. The restriction of Yb ions to the growth of NCs is responsible for these effects. Thus, higher Yb concentration forms smaller Ag NCs, whose excitation at 355 nm leads to more efficient ET to Yb ions compared to 410 nm. These findings have potential applications in the visible to near-infrared regions, such as tunable CW laser sources and photovoltaic devices.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10097269PMC
http://dx.doi.org/10.3390/nano13071177DOI Listing

Publication Analysis

Top Keywords

tunable visible
8
visible emission
8
energy transfer
8
geo-pbo glasses
8
ncs
6
ions
5
silver nanoclusters
4
nanoclusters tunable
4
emission energy
4
transfer ions
4

Similar Publications

Photonic crystals (PC) play a key role in optical field modulation due to their unique photonic band gaps (PBGs). Anodic aluminum oxide (AAO) prepared by pulse anodization is a promising candidate for PC devices. In this research, an AAO-based PC with multi-band was fabricated on a single-slice & single-material film, which exhibits multi-band responses in the visible-to-near-infrared (vis-NIR) region.

View Article and Find Full Text PDF

Distributed feedback lasers, which feature rapid wavelength tunability, are not presently available in the yellow and orange spectral regions, impeding spectroscopic studies of short-lived species that absorb light in this range. To meet this need, a rapidly tunable laser system was constructed, characterized, and demonstrated for measurements of the NH radical at 597.4 nm.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates how varying concentrations of Zn ions affect the optical properties of BaNiZnFeO ferrites, showcasing the ability to tune the band gap through Zn doping.
  • X-ray diffraction (XRD) confirmed that the material maintained a single-phase structure and exhibited changes in grain size and lattice parameters with increased Zn content.
  • UV-visible spectroscopy demonstrated that the band gap and electrical properties improved with higher Zn concentrations, indicating potential uses in optoelectronics and energy storage applications.
View Article and Find Full Text PDF

Organic Metasurfaces with Contrasting Conducting Polymers.

Nano Lett

January 2025

Second Physics Institute, University of Stuttgart, Pfaffenwaldring 57, 70569 Stuttgart, Germany.

Conducting polymers have emerged as promising active materials for metasurfaces due to their electrically tunable states and large refractive index modulation. However, existing approaches are often limited to infrared operation or single-polymer systems, restricting their versatility. In this Letter, we present organic metasurfaces featuring dual conducting polymers, polyaniline (PANI) and poly(3,4-ethylenedioxythiophene) (PEDOT), to achieve contrasting dynamic optical responses at visible frequencies.

View Article and Find Full Text PDF

Typical biosensing platforms are based on the "lock-and-key" approach, providing high specificity and sensitivity for environmental and food safety monitoring. However, they are limited in their ability to detect multiple analytes simultaneously. With the use of pattern identification methods, biosensor arrays can detect faint fluctuations caused by multiple analytes with similar properties in complex systems.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!