A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Shear Bond Strength and Fluoride Release of a Universal Adhesive: An In-Vitro Study on Primary Teeth. | LitMetric

This investigation aimed to assess the shear bond strength and fluoride-releasing capabilities of Clearfil Universal Bond Quick (Kuraray Noritake Dental Inc., Tokyo, Japan). Forty-four extracted primary molars were divided into two groups, and the enamel substrate was prepared for evaluating shear bond strength. Scotchbond (3M ESPE) and Clearfil UBQ were used to bond composite-to-enamel substrates in each group ( = 22). Shear bond strength was measured using a universal testing device and compared. Sixteen discs (6 mm diameter and 3 mm thickness) were fabricated from each Clearfil UBQ, Fuji IX, and Fuji II LC. Over the course of 30 days, each materials' fluoride release was examined and compared using ion analysis. Results revealed that Clearfil UBQ had statistically similar shear bond strength to Scotchbond. Between the three materials, Clearfil UBQ had the lowest fluoride release at baseline (0.11 ± 0.25) and the lowest cumulative fluoride release (0.12-0.27 ppm) over 30 days. Fuji IX had the highest fluoride release at baseline (19.38 ± 2.50) and cumulatively (40.87 ± 4.03 ppm), followed by Fuji II LC. We conclude that Clearfil UBQ and Scotchbond showed comparable bond strengths to the enamel. Fluoride release was seen in Clearfil UBQ in the initial two days of the 30-day period. The amount of fluoride release was significantly less than with glass ionomer cements.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10095296PMC
http://dx.doi.org/10.3390/ma16072573DOI Listing

Publication Analysis

Top Keywords

fluoride release
28
clearfil ubq
24
shear bond
20
bond strength
20
strength scotchbond
8
release baseline
8
fluoride
7
release
7
bond
7
clearfil
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!